Outlet Valve; Pressure Control Valve; Typical Wear Parts - WAGNER SuperFinish 17ex Operating Manual

Pneumatic driven unit for the airless atomization of different painting materials.
Table of Contents

Advertisement

Available languages

Available languages

Super Finish 17ex
10.3

OUTLET VALVE

1. Use a 22 mm wrench to screw the outlet valve from the
paint section.
2. Carefully pull of the clasp (1) using the enclosed screwdriver.
The compression spring (2) presses ball (4) and valve seat (5)
out.
3. Clean or replace the components.
4. Check the O-ring (7) for damage.
5. Check the installation position when mounting the spring
support ring (3) (clipped onto spring (2)), outlet valve seat
(5) and seal (6), refer to gure.
10.4

PRESSURE CONTROL VALVE

1. Unscrew the pressure control valve (1) from the uid section
using a spanner (17 mm).
2. Remove the front part (2) with a spanner (15mm).
3. Press out the pin (3).
4. Replace all parts (3-6) with the parts contained in the Pin
Guide Service Set (order no. 2371647).
10.5

TYPICAL WEAR PARTS

Despite the use of high-quality materials the highly abrasive
e ect of the paints means that wear can occur at the follow-
ing parts:
Inlet valve (spare part Order No.: 0344700)
For replacing refer to Section 10.2
(failure becomes noticeable through performance loss and/or
poor or no suction)
Outlet valve (spare part Order No.: 0341702)
For replacing refer to Section 10.3
(failure becomes noticeable through performance loss and/
or poor suction) The outlet valve is usually considerably more
durable than the inlet valve. Thorough cleaning may already
help here.
7
2
1
5
5
6
REPAIRS AT THE UNIT
5 6
3 4
3
4
2
GB
1
49

Advertisement

Chapters

Table of Contents
loading