1
Safety instructions
Electrical devices may only be mounted and connected by electrically skilled persons.
Serious injuries, fire or property damage possible. Please read and follow manual fully.
Danger of electric shock. Always disconnect before carrying out work on the device or load. In
so doing, take all the circuit breakers into account, which support dangerous voltages to the
device and or load.
These instructions are an integral part of the product, and must remain with the end customer.
2
Device components
(1)
Programming menu icons
(2)
Setpoint temperature, actual temperature or cur-
rent time
(3)
active mode
(4)
Operating area
Icons in the display
ƴ
Manual mode is active.
Ƶ
Temperature value is regulated to comfort temperature
ƶ
Temperature value is regulated to reduction temperature
ƾ
Cooling icon lights up: no cooling is taking place
Cooling icon flashes: cooling is taking place
ƿ
Heating icon lights up: no heating is taking place
Heating icon flashes: heating is taking place
Icons of the operating area (4)
Ƨ
Step back / display current time
32401502
10867379
Figure 1: Display and operating area
02.07.2020
1 / 15

Advertisement

Table of Contents
loading

Summary of Contents for Gira System 3000

  • Page 1 System 3000 Room temperature controller Display, Room temperature controller BT Room temperature controller Display Order no.: 5393 .. Room temperature controller BT Order no.: 5394 .. Operating instructions Safety instructions Electrical devices may only be mounted and connected by electrically skilled persons.
  • Page 2: Intended Use

    – Operation and programming with mobile end device (smartphone or tablet) via Bluetooth with app (Bluetooth version only) – Operation on room temperature controller insert or switch insert from system 3000 Product characteristics – Timer with three memory areas Comfort and reduction time for Mo-Fr and Sa-Su in each memory area –...
  • Page 3: Functional Description

    System 3000 Room temperature controller Display, Room temperature controller BT Functional description Heating and cooling operating mode Modern heat pump systems often also provide the option of cooling rooms. This function is sup- ported by the cover by means of the "Heating and cooling" operating mode. In this operating mode the system permanently regulates the temperature to the set cooling temperature.
  • Page 4 System 3000 Room temperature controller Display, Room temperature controller BT ature. If the maximum temperature is exceeded, the floor heating will be switched off until the floor temperature is below the maximum value again. This way, an unpleasantly hot floor is avoided.
  • Page 5 Install app on a mobile end device (Bluetooth version only) Requirement for operation via app is a mobile end device with Bluetooth interface, running the Android operating system or iOS. Download and install the Gira System 3000 App from the App Store (iOS) or Google Play ■ Store (Android).
  • Page 6: Operation

    YES and confirm once again with ƨ. The Ʃ icon flashes in the display. The coupling mode is active for one minute. ■ Start Gira System 3000 App and search for device to be coupled (paired). "Thermostat" is displayed in the app. ■...
  • Page 7: Activate Functions

    System 3000 Room temperature controller Display, Room temperature controller BT Activating the holiday mode (Bluetooth version only) The holiday mode can only be set and activated via the app. When the holiday mode is active, the display indicates the setpoint temperature for the holiday period and switches between the ƶ...
  • Page 8 System 3000 Room temperature controller Display, Room temperature controller BT Programming menu overview Figure 4: Programming menu ƙ Ʀ Three memory areas for comfort and reduction temperature for the two weekday Ʊ blocks Mo - Fr and Sa - Su Ʃ...
  • Page 9 System 3000 Room temperature controller Display, Room temperature controller BT The flashing switching time can be changed with the – or + button and saved with the ƨ but- ton. The times for comfort and reduction temperature can be saved consecutively for the week- day blocks Mo-Fr and Sa-Su each.
  • Page 10 System 3000 Room temperature controller Display, Room temperature controller BT ■ Press and hold the ƨ button and additionally press the + button for the comfort temper- ature Ƶ for more than 1 second. Press and hold the ƨ button and additionally press the – button for the reduction temper- ■...
  • Page 11: Technical Data

    System 3000 Room temperature controller Display, Room temperature controller BT DANGER! Mortal danger of electric shock Disconnect the device. Cover up live parts. Fitting the device Switch or room temperature controller insert are mounted and connected properly (see instruc- tions of the relevant inserts).
  • Page 12 System 3000 Room temperature controller Display, Room temperature controller BT Transmitting range typ. 10 m 12 Parameter list (Bluetooth version only) Adjustable parameters via app Device parameters Parameters Setting options Explanations Default setting Setting the oper- Comfort and standby, ex-...
  • Page 13 System 3000 Room temperature controller Display, Room temperature controller BT Parameters Setting options Explanations Default setting Floor: The room temperature is measured using the remote sensor. The internal temperature sensor is deactivated. Room and floor: The room temperature is measured using the internal temperature sensor or the brightness/ temperature sensor, if taught in.
  • Page 14: Warranty

    13 Conformity Gira Giersiepen GmbH & Co. KG hereby declares that the radio system type art. no. 5394 .. meets the directive 2014/53/EU. You can find the full article number on the device. The com- plete text of the EU Declaration of Conformity is available under the Internet address: www.gira.de/konformitaet...
  • Page 15 System 3000 Room temperature controller Display, Room temperature controller BT Gira Giersiepen GmbH & Co. KG Elektro-Installations- Systeme Industriegebiet Mermbach Dahlienstraße 42477 Radevormwald Postfach 12 20 42461 Radevormwald Deutschland Tel +49(0)21 95 - 602-0 Fax +49(0)21 95 - 602-191 www.gira.de info@gira.de...

Table of Contents