7 PROGRAMMING
Y40 to Y5F
X20 to X3F
D102 to D105
D202 to D205
7- 7
2) When MOV instruction is used
CPU module
Output (Y)
QY41P outputs
Input (X)
QX41 inputs
Device (D)
DA conversion value
output to Q64DA
AD conversion value
input from Q64AD
1: Data are read from Input (X) or written to Output (Y) using the BMOV instruction.
2: The output receive area data are read to D102 to D105 using the BMOV instruction.
The data in D102 to D105 are written to the Q64DA.
3: Data of the Q64AD are read to D202 to D205 beforehand.
With the BMOV instruction, the data in D202 to D205 are written to the input receive area.
REMARKS
Refer to Section 5.2.1 for the data module setting.
Output receive area
*1
Data module 1
(Output, 2 words)
Data module 3
(Output, 4 words)
*2
*1
Empty
Input send area
Data module 0
(Input, 2 words)
*3
Data module 2
(Input, 4 words)
Empty
MELSEC-Q
QJ71PB93D
0(0
)
H
1(1
)
H
2(2
)
H
3(3
)
H
4(4
)
H
5(5
)
H
6(6
)
H
191(BF
)
H
256(100
)
H
257(101
)
H
258(102
)
H
259(103
)
H
260(104
)
H
261(105
)
H
262(106
)
H
447(1BF
)
H
7 - 7