Download Print this page
REMKO PG 12 Operating Instructions Manual

REMKO PG 12 Operating Instructions Manual

Hide thumbs Also See for PG 12:

Advertisement

!
"
#

Advertisement

loading

Summary of Contents for REMKO PG 12

  • Page 1 "...
  • Page 3 Make sure to read these instructions carefully before starting/using the unit! Our guarantee will become void when the unit supplied by us is used and installed for inadequate purposes, or maintained incorrectly, etc., or if it is changed without our prior consent. Seite Seite Safety Hints...
  • Page 4 # & " When using this unit make sure always to observe the The unit may be operated only by those persons who applicable building and fire protection regulations as have been instructed regarding the unit’s operation well as the rules of the trade cooperative association. and the handling of liquid gas.
  • Page 5 Important Installation Hint When installing or removing the gas hose make sure to Make sure to charge a person with the operation of the exert a counterpressure on the gas connection unit and with the supervision of the reservoirs and of nipple of the unit using an open-end spanner SW 19 the bottle stock who has been instructed sufficiently re- and observing the left-handed thread.
  • Page 6 Assembly of Multi-bottle Set To avoid intensive icing of the gas bottle during a lon- Press down pin (2) of thermoelectric ger operation of the unit, we recommend that you use a gas valve (safety pilot). bottle battery consisting of at least 3 bottles. All bottle valves must be open to ensure regular gas supply! gas hose to unit After approx.
  • Page 7 Disassembly for Cleaning When the unit is being maintained, set or Depending on the operation conditions the units are to repaired, the gas supply has to be cut off and be tested by an expert when necessary, but at least re- the mains plug has to be unplugged from the gularly every two years, to ensure their safe operation.
  • Page 8 The orderer or the customer must have properly filled out the “guarantee certificate” which is enclosed with every REMKO automatic heater and must have returned it to REMKO GmbH & Co. KG within a timely acceptable period based on the sale and commissioning, to be entitled to...
  • Page 9 & . %! trouble: cause: – unit doesn’t start 1 – 2 – 3 – 4 – 7 – unit stops during operation 2 – 4 – 7 – 12 – 13 – fan blows, but gas supply is blocked 4 –...
  • Page 10 We reserve the right to make modifications in dimensions and construction in the interests of technical progress.
  • Page 11 & PG 12 Fig.No. Description EDV-Nr. transport handle 1101142 outside casing 1103801 inside casing 1103802 retaining ring 1103811 blow out protection grille 1103803 Gas burner 1103804 ignition electrode 1103818 terminal strip, 4er 1101442 base 1103805 foot rest 1103806 traction relief...
  • Page 12 REMKO GmbH & Co. KG Klima- und Wärmetechnik D-32791 Lage Im Seelenkamp 12 • D-32777 Lage Postfach 1827 • Telefon (0 52 32) 606 - 0 Telefax (0 52 32) 606260...