Our guarantee will become void when the unit supplied by us is used and installed for inadequate purposes, or maintained incorrectly, etc., or if it is changed without our prior consent. Subject to alterations! Stationery slow combustion heater REMKO Allmat Contents Contents Page Page...
The blow-out grille may not be closed. ◊ The fire and furnace door must be shut after the unit The REMKO ALLMAT works on the principle of sub- is warmed up and during operation. heating using exhaust post-combustion. The feeder ◊...
Wood, dry Peat, pressed BIMATIK Heat Output Regulator. Lignite briquettes The REMKO ALLMAT is equipped with a BIMATIK ther- mal output regulator. Coke This automatically regulates the heat output that has Anthracite been set on the regulator knob in the “min / max” area.
Installation The exhaust connection may only be used with ap- The unit may only be installed in accordance with the proved chimneys. The chimneys can be made of bricks applicable legal regulations and the ordinance on heat- or metal. If the chimney is made of brick, make sure ing systems.
0,3 mbar / 3 mm WS Connection Ø 150 mm EDV-NO. 1034250 AS-1000-D When using the chimney draught stabiliser, the ex- haust flap on the ALLMAT must be opened all the way. The draught regulator is set using a draught AS-ÜE-D gauge! AS-500-E AS-T90-D AS-RB90-E...
Starting Heating Mode 1. Fill up the feeder chute completely once approx. 50% Important hints about operating the unit for the first of the fuel from the pre-fuelling process is burning. time! 2. Adjust the primary air slide plate in increments to Because burned refractory bricks also contain residual the appropriate setting for the fuel.
Troubleshooting Maintenance and Service Prior to starting any work make sure to pull the Regular maintenance and observance of some basic mains plug out of the mains socket! principles are required to ensure a long service life and to keep the unit functioning properly. The unit is generating too much heat or is overheated.
Exploded View Front view without front door Back view without rear plate A = Mount for fan thermostat B = Mount for BIMATIK temperature sensor Side view – sectional drawing We reserve the right to make modifications in dimensions and construction in the interests of technical progress.
“guarantee certificate” which is we will not be held responsible and our guarantee will enclosed with every REMKO-heater and has returned it become void. to REMKO GmbH & Co. KG in due time after the unit’s sale and commissioning.
Heating Adjacent Rooms The unit may only be installed within fire-resistant, non-flammable walls! Make sure that the air follows a straight path without curves. Flexible or stationary warm air channel Heat distributor flap Replace the existing cover with a cover with connections. Replace the existing adjustable blow-out grille with an adjust- able one that can be closed.