Automatic oil heater with built-in oil burner, tank and exhaust gas connection (20 pages)
Summary of Contents for REMKO CLA 50
Page 1
CLA 2 5 - 100 Aut om a t i c Oi l / Ga s Hea t er s Ed i t i on GB- 7 0 9 Op er a t i on Tech n ol og y Or i g i n a l REM KO Sp a r e Pa r t s...
Op er a t i n g i n st r uct i on s Make sure to read these instructions carefully before starting/using the unit! Our guarantee will become void when the unit supplied by us is used and installed for inadequate purposes, or maintained incorrectly, etc., or if it is changed without our prior consent.
I n st a l l a t i o n Re q u i r e - Sa f et y Hi n t s m en t s When using this unit make sure always to observe the applicable building- and fire-protection regula- The heaters may only be installed and operated in com- tions as well as the rules of the trade cooperative pliance with the relevant regulations, especially regula-...
The waste gas pipes must reach at least beyond the ea- We recommend that a burner cover (REMKO accesso- ries) is used. ves but preferrably above the roofridge to avoid counter- Installation in closed, well aerated rooms wi- pressure due to bad weather conditions (e.g.
Sa f et y Fa ci l i t y St a r t i n g Make sure to charge a person with the operation and Triple combination control according to DIN 3440 supervision of the unit who has been instructed The device has 3 functions: sufficiently regarding the handlings concerned.
Hot Air Distribution All the units are equipped with silent and nearly main- Connect unit plug (2) to a suitable tenance-free axial fans. mains socket (230V/1 ~ 50Hz). Hot air may be distributed only in accordance with the fan capacity of the units concerned. The possible hose/pipe lengths depend on the resis- tance on the air side of the used air ducts.
Special cleaning sets • Have the waste gas values of the oil or gas burner can be obtained as accessories to the REMKO in- dustrial vacuum cleaner. checked regularly by authorized experts. For safety reasons we recommend that you conclude Install burner;...
Li st of sp a r e p a r t s CLA CLA 25 CLA 40 CLA 50 CLA 100 Fig.-No. description EDV-Nr. EDV-Nr. EDV-Nr. EDV-Nr. 1102502 1102502 1102703 1108357 base plate side cover - left/right 1102503 1102503 1102704...
Tech n i ca l Da t a Series CLA 25 CLA 40 CLA 50 CLA 100 rated heat power max. ratedheat output 26,5 rated air output m³/h 1150 1600 3200 5200 fuel h e a t i n g...
Any claims under guarantee regarding materials can be accepted only when the orderer or his customer has filled in completely the “guarantee certificate” which is enclosed with every REMKO-heater and has returned it to REMKO GmbH & Co. KG in due time after the unit’s sale and commissioning.
Page 12
REMKO GmbH & Co. KG Klima- und Wärmetechnik D-32791 Lage · Im Seelenkamp D-32777 Lage · Postfach 1827 Telefon (0 52 32) 606 - 0 Telefax (0 52 32) 606260...