Download Print this page

Electrical Specifications - AEMC SR701 User Manual

Ac current probe

Advertisement

2.25" (57mm)
1.71"
(43.5 mm)
SR701 SR704

ELECTRICAL SPECIFICATIONS

Current Range:
1mA to 1200A AC
Transformation Ratio: 1000:1
Output Signal: 1mA AC/A AC (1A AC at 1000A)
Accuracy and Phase Shift*:
Accuracy:
1mA to 100mA: ±3% Reading ± 5mA
0.1 to 1A:
±2% Reading ± 3mA
1 to 10A:
±1% Reading
10 to 100A:
±0.5% Reading
100 to 1200A:
±0.3% Reading
4.37" (111mm)
3.98" (101mm)
2.13"
(54.1mm)
3.90" (99 mm)
1.22" (31mm)
Tactical
Barrier
(keep hands below
this barrier)
1.38"
(35 mm)
1.77"
(45 mm)
Phase Shift:
1mA to 100mA: Not Specified
0.1 to 1A:
1 to 10A:
10 to 100A:
100 to 1200A:
*Reference conditions: 23°C±3°K, 20 to 75% R H,
48 to 65H z, ex ternal mag netic f ield < 40A/m, no
DC component, no ex
conductor, test sample centered.
Load impedance
Overload: 1200A for 40mn on, 20mn off
Accuracy: Per IEC 185
Not Specified
2°
1°
0.7°
ternal cur rent car rying
1.