Download Print this page

Electrical Specifications; Safety Specifications; Ordering Information; Mechanical Specifications - AEMC MN126 User Manual

Advertisement

ELECTRICAL SPECIFICATIONS

Current Range: 10mA to 12A
Output Signal: 100mV
Accuracy *:
10mA to 10A: 2% ± 0.01mV
(with non inductive load)
Phase Shift: N/A
(*Reference conditions: 23°C ± 3°K, 20 to
70% RH, external magnetic field < 40 A/m,
50 to 60Hz sine wave, no DC component, no
external current carrying conductor, test
sample centered.) Load impedance 1MΩ.
Overload:
20A continuously
Frequency Range:
45 to 65Hz
Load Impedance:
1MΩ
Working Voltage:
300V on insulated conductor
Common Mode Voltage:
100V
Cat. III
AC

MECHANICAL SPECIFICATIONS

Operating Temperature:
-13° to 122°F (-25° to 50°C)
Storage Temperature:
-40° to 176°F (-40° to 80°C)
Maximum Cable Diameter:
0.43" Ø max. (11mm)
Dimensions:
1.4 x 4.53 x 0.87"
(36 x 115 x 22mm)
Weight:
160 g (6 oz)
Colors:
Dark gray handles with red cover
, continuous
AC
/A
(1V @ 10A)
AC
AC
Polycarbonate Material:
Handle: 10% Fiberglass charged polycarbonate
UL 94 V0
Output:
Double/reinforced insulated 5 ft (1.5 m) lead with
safety 4mm banana plug

SAFETY SPECIFICATIONS

Electrical:
300V working voltage on insulated conductor
100V max common mode between output and
ground, Cat. III
3kV 50/60Hz dielectric for 1mn

ORDERING INFORMATION

AC Current Probe MN126............... Cat #2129.15
Accessories:
Banana plug adapter
(to non-recessed plug) ..................... Cat #1017.45

Advertisement