Download Print this page

Electrical Specifications - AEMC MN375 User Manual

Ac current probe

Advertisement

2.56"
(65 mm)
.83"
(21 mm)

ELECTRICAL SPECIFICATIONS

Nominal Range: 10A
Measurement Range: 0.1 to 10A
Transformation Ratio: Voltage output
Output Signal: 100mV/A (1 V at 10A AC)
Accuracy and Phase Shift*:
Accuracy:
0.1 to 1A: 1% Reading ± 2mV
1 to 10A:
1% Reading ± 1.5mV
2.00"
(51 mm)
.73"
(18.5 mm)
Tactical
Barrier
(keep hands below
this barrier)
.1.18"
Phase Shift:
1 to 5A:
 1° @ 60 Hz
5 to 10A:
 1.5° @ 60 Hz
(*Reference condi tions: 20°C to 26°C , 20 to 75% R
external mag netic f ield < 40 A/m, 48 to 65 Hz sine wave,
distortion f actor l ess than 1%, no
external current carrying conductor, test sample centered.)
Load impedance > 1M.
Frequency Range: 40 to 3kHz
Limit Operating Conditions:
20A permanently to 1kHz
Black
(30 mm)
DC component, no
Red
H,

Advertisement