Specifications; Electrical Specifications - AEMC 565 User Manual

Trms leakage current clamp-on meter
Hide thumbs Also See for 565:
Table of Contents

Advertisement

Reference Conditions: Accuracy given at 73°F ± 9°F, 80% RH, Con-
ductor Centered in A, Sine wave 48-65Hz, No AC Magnetic Field,
External Magnetic Field <40A/m, True RMS (no DC component) for V,
A and mA accuracy are specified from 5% to 100% of range. Accuracy
add ±1% of Reading on Crest Factor 1.4<CF<3 at full-scale & CF<6
at mid-scale.
3.1 Electrical Specifications
mA Current
Range
60mA
600mA 100µA
Max Voltage to Ground: 600V
AC Current
Range
10A
100A*
Max Voltage to Ground: 600V
10
roducts Online at:
CHAPTER 3

SPECIFICATIONS

(TRMS, Auto-ranging)
Res
1.2% Rdg ± 5cts (50 to 60Hz)
10µA
2.5% Rdg ± 5cts (50 to 500Hz)
3.5% Rdg ± 10cts (500 to 3kHz)
(TRMS, Auto-ranging)
Res
1.2% Rdg ± 5cts (50 to 60Hz)
1mA
2.5% Rdg ± 5cts (50 to 500Hz)
3.5% Rdg ± 10cts (500 to 3kHz)
1.2% Rdg ± 5cts (50 to 60Hz)
2.5% Rdg ± 5cts (50 to 500Hz)
3.5% Rdg ± 10cts (500 to 3kHz)
10mA
*80 to 100A:
5.0% Rdg ± 5cts (50-60Hz)
GlobalTestSupply
www.
Accuracy
Accuracy
Clamp-on Meter Model 565
Max
150Arms
Max
150Arms
.com
sales@GlobalTe

Advertisement

Table of Contents