Lubrication - Mec 4069RT Service And Parts Manual

Hide thumbs Also See for 4069RT:
Table of Contents

Advertisement

L
UBRICATION
Controls Module

Lubrication

No.
ITEM
SPECIFICATION
1
Hydraulic
Normal ambient temperatures
Reservoir
Mobile Fluid DTE 10, DTE 13 M, or AW32
Ambient temperatures below 0° F (-18° C)
Chevron Rando Premium MV
Fill to the middle of the sight gauge with platform in the
stowed position and outriggers retracted.
2
Hydraulic Filter
Filter Element
(located inside Hydraulic Reservoir)
Hydraulic
Reservoir
Filter
Housing
Sight
Gauge
components removed
for clarity
Do not substitute other fluids
as pump damage may result.
"4069RT" Service and Parts Manual
Figure 3-8: Lubrication Points
ART_3816
FREQUENCY
Routine Maintenance
Check sight gauge level daily
Scheduled Maintenance
Change yearly or every 600 hours,
whichever occurs first
Scheduled Maintenance
Normal Conditions
Change every six months or 300 hours, whichever
occurs first
Severe Conditions--very dusty, exceptionally hot
or exceptionally cold conditions
Change every three months or 150 hours,
whichever occurs first