Eplan Adaptations; Settings Via "Siemens Dq-Topo" Add-In; Minimum Requirements In Eplan Regarding Drive-Cliq Topology - Siemens SINUMERIK 840D sl Operating Manual

Sinumerik integrate create myconfig - eplan electric p8 add-in
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

EPLAN adaptations

6.1

Settings via "Siemens DQ-Topo" add-in

The SINAMICS product catalog is selected and imported via the "Siemens DQ-Topo" add-in.
The entries in the EPLAN database can be changed for export of the DQ configuration.
You will find further information on this in Section "Settings (Page 17)".
6.2

Minimum requirements in EPLAN regarding DRIVE-CLiQ topology

The DRIVE-CLiQ topology describes the drive bus system. As with every bus system, the first
step is to define a master module.
Master modules
The DRIVE-CLiQ types (EPLAN database field) listed below are recognized as master
modules:
Table 6-1
Master modules
DRIVE-CLiQ type
SIMOTION_CX
SINAMICS_CU
SIMOTION_CPU
SIMOTION_CPU_C
SIMOTION_CPU_D
SIMOTION_CPU_P
SINUMERIK_NCU
SINUMERIK_NX
Marking as a master module is specified via the DRIVE-CLiQ type entry.
Pre-defined DRIVE-CLiQ/encoder connection names
Pre-defined DRIVE-CLiQ connection names for SIEMENS devices:
● X100, X101, X102, X103, X104, X105
● X200, X201, X202, X203, X204, X205
● X400, X401, X402
● X500, X500/1, X500/2, X501, X502, X503, X504, X505
SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In
Operating Manual, 12/2017, A5E43099659B-AA
Description and examples
Controller Extension for SIMOTION D4x5/D4x5-2
Control Unit of SINAMICS S120, e.g. CU320/CU320-2
Control Unit/Controller of SIMOTION C/D/P
Controller of SIMOTION C
Control Unit of SIMOTION D with SINAMICS CU320/CU320-2 integrated
Control Unit of SIMOTION P
Numerical Control Unit of SINUMERIK 840D/840Dsl/828D
Numerical Extension for SINUMERIK 840D/840Dsl/828D