2.2.3 Performing the testing

2.2.3.1 Performing the local testing

To perform the local testing, please use the REVIEW mode.
Please place the device in proper areas of the inspected surface and press the trigger button. Further it is necessary to
study the received image of the section and to draw a conclusion, whether the received data is enough for decision-making or
where it is necessary to remove the device for more detailed information. The data received in this mode are not automatically
recorded, therefore, if necessary, it shall be written down manually, as separate shots. To review the saved data, it is possible
to load them into the REVIEW mode.
After receiving the necessary information to make a decision, the work in this mode can be finished.

2.2.3.2 Performing the continuous testing

To perform the continuous testing, please use the MAP mode.
Please place the device on the area, marked on the inspected object and press the trigger. Then move the device to the next
position. The currently marked pattern is inspected this way and further all marked patterns are inspected.
When receiving first images shown in the screen, preliminary conclusions about the inspected object can be done. It is
necessary to do the final conclusions on a PC after all the necessary data are received and processed by the software.