1.3.5 Systems and condition indication

For your convenience the trigger button is located on the handle. By pressing this button, the signal transmission and
reception starts.
By pressing the trigger button, the field for data collection appears.
NOTE: TO OBTAIN CORRECT RESULTS OF INSPECTION DO NOT MOVE THE DEVICE AND WEAKEN THE CLAMPING DURING
THE DATA COLLECTION PROCESS!
After the completion of data collection, the indicating field changes its color
from red to green – the calculation of data is going.

1.3.6 Operation modes

The tomograph has two main operation modes, as well as an adjustment
function of the inspection parameters for each testing object suitable for further
on-line selection. The device allows to select different types of data represen-
tation on the screen during operation depending on the used operation mode.
REVIEW MODE
This mode is used for quick viewing of the internal structure of the testing
object in random places. The B-Scan is displayed on the screen to a depth up to
2.5 meters. (Figure 12).
Additionally the following procedures are performed in this mode:
- automatic determination of the propagation velocity of ultrasonic waves
- measurement of the coordinates and image levels in the tomogram
- thickness measurement of the testing object
- save and view В-Scans
-view A-Scans.