4.2

Camera Models

815 CCD and 515 CCD Cameras
Specifications
Type
Resolution
Bit Depth
Quantum Efficiency
Cooling
Binning
PC Interface
4.3

Ethidium Bromide (EtBr) emission filter

The ethidium bromide (50 mm
radiation emitted from the transilluminator. The filter is placed in the slide-out filter wheel
assembly on the side of the Imager. The filter allows visualization of fluorophores from 580 -
630 nm, targeting the ethidium bromide emission peak of 605 nm.
Additional filters are available for other specific fluorophores. Filters can also be removed when
imaging non-fluorescent media (including chemiluminescent blots, protein gels, colony plates,
etc.) in order to produce brighter images.
4.4

Transilluminator

The GelDoc-It
transilluminator models. UVP offers a variety of transilluminator configurations, including
Benchtop models with multiple wavelengths and variable intensities as well as the highly
uniform, patented FirstLight
included with your system.
4.5

Fluorescent Focus Target

The Fluorescent Focus Target fluoresces when placed
on a UV transilluminator or when exposed to overhead
UV. The Target provides sharp fluorescent images to
aid in adjusting the lens and camera settings for ideal
imaging results.
81-0220-01 Rev R
815 CCD
CCD, Monochrome
3296 x 2472, 8.1 MP
16 bit
50 % peak
- 57 °C from ambient
Yes, 1 x 1 through 8 x 8 Yes, 1 x 1 through 8 x 8
USB2.0
2
) UV-blocking bandpass interference filter blocks UV and IR
2
and ChemiDoc-It
®
transilluminator. Refer to the packing slip for the transilluminator
Note: For UV protection and to extend the life of the UV transilluminator, the system
incorporates a ten-minute transilluminator shutoff timer. The timer shuts off the
transilluminator after ten minutes of operation. A push button on the front of the
darkroom allows the user to reset the timer. Alternately, the timer can also be reset by
opening and closing the darkroom door.
515 CCD
CCD, Monochrome
2.1 MP
16 bit
50 % peak
- 57 °C from ambient
USB2.0
Imagers can accommodate UVP's Benchtop and FirstLight
2