Technical Data
8.1.
General terms
Operating pressure:
Max. control air pressure for CPV:
Max. control air pressure for CPV with booster: 4 bar
Operating temperature:
short-term:
Air connections:
8.2.
Compressed air quality
Quality class according to DIN ISO 8573-1
- content of solid particles:
- content of water:
- content of oil:
The oil applied must be compatible with Polyurethane
elastomer materials.
UK
7 bar
6 bar
135°C
140°C
G1/8"
quality class 3,
max. size of solid particles
per m³
10000 of 0,5 µm < d < 1,0 µm
500 of 1,0 µm < d < 5,0 µm
quality class 3,
max. dew point temperature
-20°C
For installations at lower
temperatures or at higher al-
titudes, additional measures
must be considered to reduce
the pressure dew point accor-
dingly.
quality class 1,
max. 0,01 mg/m³