Autoreset - Leuze electronic SOLID-2SF-M Connecting And Operating Instructions

Hide thumbs Also See for SOLID-2SF-M:
Table of Contents

Advertisement

Troubleshooting
Code Cause/meaning
E 06
Short circuit of an SSD against GND or cross
connection between two SSDs or between SSD and
Dyn SSD
E 07
Short circuit of an SSD against +24V DC or cross
connection between two SSDs or between SSD and
Dyn SSD
E 14
Power supply undervoltage
E 18
Test time-limit exceeded
E 22
Power supply cable overvoltage
Table 7.2:
7.3

AutoReset

After an error or a fault has been detected and displayed, an automatic restart occurs within
• about 2 seconds for the Transmitter
• about 20 seconds for the Receiver
for the device in question. If the error or fault is then no longer present, the machine or
system can be started again.
26
Receiver diagnostics
SOLID-2SF-M
Measure to eliminate error
Eliminate cross connection
Eliminate cross connection
Check/replace power supply or load
Test time > 150 ms; check external test
Check power supply/load
Leuze electronic