8

Technical data

8.1

General data

8.1.1

Beam data

Range
Min.
0.25 m
Table 8.1:
8.1.2

Safety relevant technical data

Type in accordance with IEC/EN 61496
SIL in accordance with IEC 61508
SILCL in accordance with IEC/EN 62061
Performance Level (PL) in accordance with ISO 13849-1: 2008
Category in accordance with ISO 13849
Average probability of a failure to danger per hour (PFH
For protective field heights up to 900 mm, all resolutions
For protective field heights up to 1800 mm, all resolutions
For protective field heights up to 2850 mm, all resolutions
Service life (T
8.1.3

General system data

Safety category
Supply voltage U
Transmitter and Receiver
Residual ripple of supply voltage
Transmitter power consumption
Receiver power consumption
Shared value for external fuse in the
supply line for Transmitter and Receiver
Leuze electronic
Number of beams
Max.
6 m
Beam data
)
M
v
SOLID-2SF-M
Min.
Max.
2
4
Type 2 in acc. with EN IEC 61496; SIL 1 in acc. with IEC
61508
24V DC, ± 15 %, external power supply with secure mains
supply isolation and equalization for a 20 ms power outage,
minimum 1 A current reserve
± 5 % within U
limits
v
45 mA
80 mA without external load
1A
Technical data
Beam distances
Min.
200
)
d
Max.
400
Type 2
SIL 1
SILCL 1
PL c
Cat. 2
-8 1
8.2 x 10
/
h
-8 1
8.9 x 10
/
h
On request
20 years
27