Check-line DC**-3000PS series Operating Instructions Manual

Check-line DC**-3000PS series Operating Instructions Manual

Coating thickness gauge

Advertisement

Quick Links

15.0
WARRANTY
Checkline Europe (Checkline) warrants to the original purchaser that this product is
of merchantable quality and confirms in kind and quality with the descriptions and
specifications thereof. Product failure or malfunction arising out of any defect in
workmanship or material in the product existing at the time of delivery thereof which
manifests itself within one year from the sale of such product, shall be remedied by
repair or replacement of such product, at Checkline's option, except where
unauthorized repair, disassembly, tampering, abuse or misapplication has taken
place, as determined by Checkline. All returns for warranty or non-warranty repairs
and/or replacement must be authorized byCheckline, in advance, with all repacking
and shipping expenses to the address below to be borne by the purchaser.
THE FOREGOING WARRANTYIS IN LIEU OF ALL OTHER WARRANTIES,
EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO, THE
WARRANTYOF MERCHANTABILITYAND FITNESS FOR ANYPARTICULAR
PURPOSE OR APPLICATION. CHECKLINE SHALL NOT BE RESPONSIBLE NOR
LIABLE FOR ANYCONSEQUENTIAL DAMAGE, OF ANYKIND OR NATURE,
RESULTING FROM THE USE OF SUPPLIED EQUIPMENT, WHETHER SUCH
DAMAGE OCCURS OR IS DISCOVERED BEFORE, UPON OR AFTER
REPLACEMENT OR REPAIR, AND WHETHER OR NOT SUCH DAMAGE IS
CAUSED BYMANUFACTURER'S OR SUPPLIER'S NEGLIGENCE WITHIN ONE
YEAR FROM INVOICE DATE.
Some State jurisdictions or States do not allow the exclusion or limitation of
incidental or consequential damages, so the above limitation may not apply to you.
The duration of any implied warranty, including, without limitation, fitness for any
particular purpose and merchantability with respect to this product, is limited to the
duration of the foregoing warranty. Some states do not allow limitations on how long
an implied warranty lasts but, not withstanding, this warranty, in the absence of such
limitations, shall extend for one year from the date of invoice.
CHECKLINE EUROPE
Dennenweg 225B, 7545 WE, Enschede
Tel: +31-53-4364262 / Fax: +31-53-4333570
Every precaution has been taken in the preparation of this manual. Checkline-Europe assumes
no responsibility for errors or omissions. Neither is any liability assumed for damages resulting
from the use of information contained herein. Any brand or product names mentioned herein
are used for identification purposes only, and are trademarks or registered trademarks of their
respective holders.
© Checkline-Europe
-24-

TABLE OF CONTENTS

1.0
.....................................................................
2.0
.....................................................................
2.1
2.2
2.3
2.4
3.0
............................................................
3.1
Power
3.2
3.3
3.4
3.5
Manually Setting the Measure Mode (DCFN version only)
3.6
3.7
4.0
.....................................................................
4.1
Measuring Using Default Calibration
4.2
4.3
4.4
Adding Zero Offset
5.0
6.0
Managing Statistical and Single Values
6.1
Selecting Statistics for display
6.2
Displaying / Printing Statistics
6.3
Displaying / Printing Single Values
6.4
Deleting Stored Values
7.0
Data Transfer
............................................................
8.0
Error Messages
............................................................
9.0
Specifications
............................................................
10.0
Measuring Limits
............................................................
11.0
Resolution Table
............................................................
12.0
Protective Shell
............................................................
13.0
Optional Accessories
...................................................
14.0
Diagram of Menu Structure
15.0
Warranty
............................................................
© Checkline-Europe
2
3
7
11
.........................................
13
...............................
14
17
18
19
20
20
21
22
.........................................
23
24
-1-

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DC**-3000PS series and is the answer not in the manual?

Questions and answers

Summary of Contents for Check-line DC**-3000PS series

  • Page 1: Table Of Contents

    15.0 WARRANTY TABLE OF CONTENTS Checkline Europe (Checkline) warrants to the original purchaser that this product is Introduction …………………………………………………………… of merchantable quality and confirms in kind and quality with the descriptions and Overview …………………………………………………………… specifications thereof. Product failure or malfunction arising out of any defect in Gauge workmanship or material in the product existing at the time of delivery thereof which Using the Gauge...
  • Page 2: Introduction

    INTRODUCTION 14.0 DIAGRAM OF MENU STRUCTURE Checkline’s 3000PS Series gauges provide precise, non-destructive digital coating After turning on the instrument, press UP or DOWN repeatedly to move to the thickness measurement on steel and non-ferrous metals. desired main section (Calibration, for example). Next, press OK to access the second level subsections within the main section.
  • Page 3: Overview

    13.0 OPTIONAL ACCESSORIES OVERVIEW Gauge Data Transfer Software Infrared Adapter Wireless Printer © Checkline-Europe © Checkline-Europe -22-...
  • Page 4: Using The Gauge

    A IR Sensor Transmits stored measurement data to a PC or printer 12.0 PROTECTIVE RUBBER SHELL equipped with an infrared adapter B LCD Screen Displays numerical data & operator prompts The gauge is supplied with a durable rubber shell that provides an added measure of physical and environmental protection in harsh applications.
  • Page 5: Display

    10.0 MEASURING LIMITS Display Minimum Radius for Convex Surfaces 3mm (0.12") Minimum Radius for Concave Surfaces 5mm (0.2") Minimum Headroom 100 mm (4") Minimum Sample Diameter 5mm (0.2") Minimum Substrate Thickness - F 0.5 mm (20 mils) 50 μm (2 mils) Minimum Substrate Thickness - NFe 11.0 RESOLUTION TABLE...
  • Page 6: Complete Kit

    Complete Kit SPECIFICATIONS 3000PS Series gauges are supplied as a complete kit, including: 0 - 1500 μm (0 – 60.00 mils) Range - Gauge Accuracy ± (1μm / 0.04 mils + 1% of reading) - Probe - Zero calibration standards (Fe-stainless and/or Al) Display Back-lit, 4-digit alphanumeric, digit height 10mm (0.4") - Calibration foils (2),...
  • Page 7: Basic Procedures

    ERROR MESSAGES BASIC PROCEDURES Faults or malfunctions identified by the instrument are indicated by an error Turning Power ON and OFF message appearing on the display: To turn the gauge on, press and hold the power switch (item H, page 3) for two Batteries are empty: seconds, until the chime sounds.
  • Page 8: Backlight

    Backlight DATA TRANSFER 3000PS Series gauges equipped with a backlight function to improve the readability of the display in certain lighting conditions. The operator can select permanent on, For data transfer from a 3000PS series gauge to a PC you must not use a possible 3-second on (after each measurement) and off: enclosed drive disc.
  • Page 9: Total Reset To Factory Defaults

    To print statistical values: Manually Setting Measurement Mode (DCFN only) 1. Press DOWN repeatedly until Statistics appears on display. In some cases, especially with varnish applied to zinc on steel, it is advisable to manually set the measuring mode—F mode (Ferrous) for measurements on 2.
  • Page 10 Replacing batteries Displaying and printing single values 1. Turn gauge over. Remove the screw on To display single values: the back using the screwdriver provided. 1. Press DOWN repeatedly until Statistics appears on display. 2. Carefully insert blade 2. Press OK. Printout of Statistics appears on the display. screwdriver at the points on the casing seam indicated in the photo;...
  • Page 11: Calibration

    MANAGING SINGLE AND STATISTICAL VALUES CALIBRATION The 3000PS gauge is provided with online Measuring Using Factory (Works) Calibration statistics. The statistical values are re- calculated and displayed in the two bottom 1. Press DOWN. Calibration appears on the display. lines after every measurement.
  • Page 12: Setting Audible Limit Alerts

    Zero Offset SETTING AUDIBLE LIMIT ALERTS In this menu item, a constant positive or negative value can be set. This value is automatically added to the measured value or subtracted from the measured value To monitor your measured values, you can set an upper and a lower limit value. every time a measurement is carried out.
  • Page 13 DCX X -3 0 0 0 PS COATING THICKNESS GAUGE Che c k line Europe Checkline Europe Tel: +31 (0)53 4364262 Dennenweg 225 B Fax: +31 (0)53 4333570 NL-7545 WE Enschede Website: www.checkline-europe.com The Netherlands Email: info@checkline-europe.com OPERAT I N G I N ST RU CT I ON S...

Table of Contents