Check-line DCF-900 User Manual

Check-line DCF-900 User Manual

Coating thickness gauge

Advertisement

Quick Links

NOTES
- 16 -
OI-809F

TABLE OF CONTENTS

1.0 Introduction & Quick Start Instructions . . . . . . . . . . . . . . . . . . . . . .
2.0 Operating Principle & Applications . . . . . . . . . . . . . . . . . . . . . . . . .
3.0 Equipment Supplied . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.0 Front Panel Layout and Functions . . . . . . . . . . . . . . . . . . . . . . . . . .
5.0 Operating Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.0 Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.1 Introduction
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.4 Notes on Calibration
7.0 Changing Units of Measure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.0 Changing the Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9.0. Maintenance, Spare Parts & Service . . . . . . . . . . . . . . . . . . . . . . . .
9.1 Maintenance
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9.2 Spare Parts & Service
10.0 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11.0 Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IMPORTANT: These instructions apply to both the DCF-900 and DCN-900
gauges except where noted otherwise.
Page
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
- 1 -
2
3
4
5
6
8
11
12
13
14
15

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DCF-900 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Check-line DCF-900

  • Page 1: Table Of Contents

    11.0 Limited Warranty ........IMPORTANT: These instructions apply to both the DCF-900 and DCN-900 gauges except where noted otherwise.
  • Page 2: Introduction & Quick Start Instructions

    Introduction & Quick Start Instructions 11.0 Limited Warranty The DCF-900 and DCN-900 Coating Thickness Gauges represent the ELECTROMATIC Equipment Co., Inc. (ELECTROMATIC) warrants to the original purchaser that this product is of merchantable quality and confirms in kind and quality latest technology for the non-destructive measurement of coatings and with the descriptions and specifications thereof.
  • Page 3: Operating Principle & Applications

    Note: Accuracy limits require that calibration be made near the measured The Model DCF-900 gauge measures the thickness of all non-mag- thickness. netic coatings, finishes and metal plating on iron, steel and other magnetic alloy surfaces. (Examples: paint,powder coatings, plastic, Resolution: 0.1 mil (1 µm)
  • Page 4: Equipment Supplied

    FAX. 516-295-4399 NTS-20 NIST Traceable Plastic Shims (5.00, 10.00, 20.00 mils / 127, 254, 508mm) If there are any questions regarding the operation of the DCF-900 or DCN-900 gauge, and before sending any unit back for repair, it NIST Certified Standards is strongly recommended that the user contact ELECTROMATIC’s...
  • Page 5: Front Panel Layout And Functions

    Changing the Battery Front Panel Layout and Functions The battery should not be removed while the power is on. Wait for the Control or gauge to automatically power off (after 90 seconds of non-use) before Device Function or Indication replacing the battery. Provides measurement value, as well as When to Replace: The gauge will automatically turn off if the battery display...
  • Page 6: Operating Procedures

    NOTE: Once selected, units of measure will remain unchanged ru.n or run. The gauge is now ready to take measurements. each time the DCF-900 is turned on and off. NOTE: The presence or absence of a decimal point on the LCD display indicates that the gauge has been set for English (mils) or metric (microns) units, respectively.
  • Page 7: Notes On Measurements

    You cannot turn the power off manually. combination and measure as before. 2. The DCF-900 and DCN-900 are continuous-reading type Note: the reading and determine if it matches the indicated value of gauges which will provide readings as long as the probe is in the shim.
  • Page 8: Calibration

    6.1 Introduction The screen will display ru.n or run, to indicate English (mils) The DCF-900 normally does not require calibration before use. or metric (microns) measuring units, respectively. To change However, whenever the productor part material to be checked units, refer to 7.0.
  • Page 9 CHECK LINE ® • DCF-900 / DCN-900 Coating Thickness Gauge Distributed by: ABQ Industrial LP USA U S E R ’ S G U I D E Tel: +1 (281) 516-9292 / (888) 275-5772 eFax: +1 (866) 234-0451 Web: https://www.abqindustrial.net E-mail: info@abqindustrial.net...

This manual is also suitable for:

Dcn-900