Fault Reference Table
Table 2 Fault Reference Table
Fault
number
Message
Type
F250
System clock
Manual
not set. Set
correct time.
F251
A device is lost.
Manual
Check
connection.
New device
Manual
F252
detected. Check
device settings.
F500
Internal failure.
Manual
Service
required.
F501
Memory failure.
Manual
Service
required.
97-0022-01-01
Cause
Action
On initial startup,
Set the clock to the correct
the clock needs to be
time. See "Using the Clock
set. The system will
Menu" on page 21.
not operate correctly
until it is.
The SCP has lost
Check network connection
communications
between the SCP and the
with another device
device.
on the network.
You have connected
Acknowledge the message
a new device to the
and check that the device
network or
is properly configured.
reconnected a
disconnected device.
The silicon serial ID
Reset the SCP by
number has failed
removing and restoring
and the SCP has
network power. If problem
gone into Standby
persists, call customer
mode.
service.
The SCP has
Reset the SCP by
suffered a non-
removing and restoring
volatile memory
network power. If problem
failure.
persists, call customer
service.
Table 2 Fault Reference Table
Fault
number
Message
Type
Internal reset.
Manual
F503
Call customer
support.
F504
Lost network
Automatic
connection.
Internal failure.
Manual
F505
See guide.
Troubleshooting
Cause
Action
The real-time clock
Reset the SCP by
in the SCP has
removing and restoring
failed.
network power. If problem
persists, call customer
service.
The SCP has lost
Check connection between
communications
the SCP and the network.
with the network
because of a faulty
connection or
electronic signal
disruption.
A controller fault
Reset the SCP by
has occurred and the
removing and restoring
SCP has gone into
network power. If problem
Standby mode.
persists, disconnect and
reconnect network cables.
33
Need help?
Do you have a question about the Xanbus System Control Panel and is the answer not in the manual?