Mounting
With electrodes, delivering continuous
measured values, the electrode must only be
installed vertically. Should the installation from
top not be possible, the electrodes can also be
mounted laterally (fig. 2.5)
Under the accessory in our pricelist you find a
screening tube and a closing cone or a bent
rod electrode by which the electrode can be
also mounted laterally. Choose the length (L) of
the screening tube such that no product
bridges can be caused between cable and
vessel wall and that the electrode cable cannot
touch the vessel wall due to product
movements. Use a fixing weight or a fixing
insulator.
Material cone
L
Fixing weight
Fig. 2.5 Continuous electrodes
20
Capacitive electrodes EL 4 ... 20 mA - compact