This symbol indicates special instructions for Ex applications. List The dot set in front indicates a list with no implied sequence. à Action This arrow indicates a single action. Sequence Numbers set in front indicate successive steps in a procedure. Conductive probe EL 4...
During work on and with the device the required personal protective equipment must always be worn. 2.2 Appropriate use EL 4 is a sensor for level detection. You can find detailed information on the application range in chapter "Product description".
The environment management system is certified according to DIN EN ISO 14001. Please help us fulfil this obligation by observing the environmental instructions in this manual: Chapter "Packaging, transport and storage" Chapter "Disposal" Conductive probe EL 4...
Components EL 4 consists of the following components: Housing cover Housing Process fitting with electrode Fig. 1: Conductive multiple rod electrode EL 4 Housing cover Housing Process fitting To create a measuring system you need one conductive probe and a VEGATOR 256C, 532 or 631 signal conditioning instrument.
EL 4 is a point level sensor with partly insulated conductive electrode for level detection. EL 4 is very rugged and can be used in all areas of industrial process technology. The level switch can be used in conductive liquids such as e.g. water.
Not exposed to corrosive media Protected against solar radiation Avoiding mechanical shock and vibration Storage and transport Storage and transport temperature see chapter "Supplement - temperature Technical data - Ambient conditions" Relative humidity 20 … 85 % Conductive probe EL 4...
Fig. 2: Measures against moisture penetration Transport Do not hold EL 4 on its electrode rods. Particularly with long rod versions, the sensor can be damaged by the weight of the instrument. Pressure/Vacuum The process fitting must be sealed if there is gauge or low pressure in the vessel.
Page 10
Inflowing medium If EL 4 is mounted in the filling stream, unwanted false measurement signals can be generated. For this reason, mount EL 4 at a position in the vessel where no disturbances, e.g. from filling openings, agitators, etc., can occur.
Page 11
Use conductive seals, such as those made of copper or lead, etc. Insulating measures, such as covering the thread with Teflon tape, can interrupt the necessary electrical connection with metal vessels. For this reason, ground the probe on the vessel or use a conductive seal material. Conductive probe EL 4...
Always keep in mind the following safety instructions: Connect only in the complete absence of line voltage Select power supply You can find the electrical connection of EL 4 in the operating instructions manual of the corresponding signal conditioning instru- ment.
Page 13
Fig. 5: Connection compartment of the probe - 220 kΩ resistance between terminals 1 and 2 Connection terminal 1 = longest rod Connection terminal 2 = shortest rod Probe with 2 rods Probe with 3 rods Probe with 4 rods Probe with 5 rods Conductive probe EL 4...
6 Set up 6 Set up 6.1 General information You can find the setup procedure for EL 4 in the operating instructions manual of the corresponding signal conditioning instrument. Conductive probe EL 4...
24 hour service hotline However, should these measures not be successful, call the VEGA service hotline in urgent cases under the phone no. +49 1805 858550. The hotline is available to you 7 days a week round-the-clock. Since we offer this service world-wide, the support is only available in the...
Page 16
7 Maintenance and fault rectification Please ask the agency serving you for the address of your return shipment. You can find the respective agency on our website www.vega.com under: "Company - VEGA worldwide" Conductive probe EL 4...
Correct disposal avoids negative effects to persons and environment and ensures recycling of useful raw materials. Materials: see chapter "Technical data" If you have no possibility to dispose of the old instrument professionally, please contact us concerning return and disposal. Conductive probe EL 4...
-40 … +80 °C (-40 … +176 °F) Process conditions Process pressure -1 … 6 bar/-100 … 600 kPa (-14.5 … 87 psig) Process temperature EL 4 of 316L -20 … +100 °C (-4 … +212 °F) Conductive of the medium min. 7.5 µS/cm...
Page 19
Depending on the version, instruments with approvals can have different technical data. For these instruments, the corresponding approval documents have to be taken into account. These are part of the delivery or can be downloaded under www.vega.com via "VEGA Tools" and "serial number search" as well as via "Downloads" and "Approvals".
Les lignes de produits VEGA sont globalement protégées par des droits de propriété intellectuelle. Pour plus d'informations, on pourra se référer au site http://www.vega.com VEGA lineas de productos están protegidas por los derechos en el campo de la propiedad industrial. Para mayor información revise la pagina web http://www.vega.com Линии...