Fuji Electric PXG-9 Communication Instruction Manual page 46

Digtal controller micro controller x communication function (rs-485 modbus)
Hide thumbs Also See for PXG-9:
Table of Contents

Advertisement

Parameter
Parameter
display
name
A A A A L L L L 4 4 4 4 h
"
"
AL4h
A A A A L L L L 5 5 5 5
"
"
AL5
A A A A L L L L 5 5 5 5 L L L L
"
"
AL5L
A A A A L L L L 5 5 5 5 h h h h
"
"
AL5h
L L L L o o o o C C C C
"
"
LoC
PID (Ch2)
Parameter
Parameter
display
name
P P P P
P
"
"
Chapter
7
I I I I
I
"
"
d d d d
D
"
"
h h h h Y Y Y Y S S S S
hYS
"
"
C C C C o o o o L L L L
CoL
"
"
d d d d b b b b
db
"
"
b b b b A A A A L L L L
bAL
"
"
A A A A r r r r
Ar
"
"
r r r r E E E E v v v v
rEv
"
"
S S S S v v v v L L L L
SvL
"
"
S S S S v v v v h h h h
Svh
"
"
T T T T C C C C 1 1 1 1
TC1
"
"
T T T T C C C C 2 2 2 2
TC2
"
"
P P P P L L L L C C C C 1 1 1 1
PLC1
"
"
P P P P h h h h C C C C 1 1 1 1
PhC1
"
"
P P P P L L L L C C C C 2 2 2 2
PLC2
"
"
P P P P h h h h C C C C 2 2 2 2
PhC2
"
"
P P P P C C C C U U U U T T T T
PCUT
"
"
Relative
Contents
address
AL4h set value
00C8
ALM5 set value or A5-L
00CE
AL5L set value
00CE
AL5h set value
00CF
Key lock
0037
Relative
Contents
address
Proportional band
0005
Integration time
0006
Derivation time
0007
ON/OFF control hysteresis
0008
Cooling proportional
0009
band coefficient
Dead band
000A
Output convergence value 000C
Anti-reset windup
000B
Sets normal/reverse
0067
operations
SV limit (lower)
002E
SV limit (upper)
002F
OUT1 proportion cycle
0068
OUT2 proportion cycle
0069
OUT1 lower limit
0028
OUT1 upper limit
0029
OUT2 lower limit
002A
OUT2 upper limit
002B
Selects the output limiter type
0027
Resistor Number
Type
Engineering
Internal
unit
40185
41185
Word
0% to 100% FS (absolute alarm)
H
40191
41191
Word
0% to 100% FS
H
40191
41191
Word
0% to 100% FS (absolute alarm)
H
40192
41192
Word
0% to 100% FS (absolute alarm)
H
40040
41040
Word
0 : no lock
H
Resistor Number
Type
Engineering
Internal
unit
40006
41006
Word
0 to 9999 (0.0% to 999.9%)
H
40007
41007
Word
0 to 32000 (0 to 3200 sec)
H
40008
41008
Word
0 to 9999 (0.0 to 999.9sec)
H
40009
41009
Word
0% to 50% FS
H
40010
41010
Word
0.0 to 100.0
H
40011
41011
Word
-50 to 50%
H
40013
41013
Word
-100 to 100%
H
40012
41012
Word
0% to 100% FS
H
40088
41088
Word
0: rv-- (heat (reverse)
H
40031
41031
Word
0% to 100% FS
H
40032
41032
Word
0% to 100% FS
H
40089
41089
Word
1 sec to 150 sec
H
40090
41090
Word
1 sec to 150 sec
H
40025
41025
Word
-3.00 to 103.00%
H
40026
41026
Word
-3.00 to 103.00%
H
40027
41027
Word
-3.00 to 103.00%
H
40028
41028
Word
-3.00 to 103.00%
H
40024
41024
Word
0 to 15
H
– 44 –
Written data
Read data
range
-100% to 100 % FS (deviation alarm)
-100% to 100 % FS (deviation alarm)
-100% to 100 % FS (deviation alarm)
1 : all lock
2 : All but SV locked
Written data
Read data
range
/ cool (none))
1: no-- (heat (normal)
/ cool (none))
2: rvno (heat (reverse)
/ cool (normal))
3: norv (heat (normal)
/ cool (reverse))
4: rvrv (heat (reverse)
/ cool (reverse))
5: nono (heat (normal)
/ cool (normal))
Factory
Dependent
Setting
on range
10°C
Dependent
Factory Setting
on range
5.0%
240 sec
60.0 sec
1°C
1.0
0%
0/50 (single/dual)
100%
rv--/rvno (single/ dual)
0% FS
100% FS
30 or 2 sec
30 or 3 sec
-3.0%
103.0%
-3.0%
103.0%
0