6.1.10 readio #

Response details
ID
Value
Example: I/O ID:3 Value:0

6.1.11 setdigout ## Y1 Y2

for OUT1 and OUT2 values.
level.
any character except 0 and 1 can be used.
remains as it was set before.

6.1.12 setdigoutX Z Y

6.1.13 getparam ####

be found in chapter number 8 "Parameter List"

6.1.14 setparam ####

IDs can be found in chapter number 8 "Parameter List"

6.1.15 getparam 1271 X/212 X

If X = 1, Operator codes from 0-19 are read from configuration and sent via SMS.
If X = 2, Operator codes from 20-39 are read from configuration and sent via SMS.
If X = 3, Operator codes from 40-49 are read from configuration and sent via SMS.
If X = any other, Operator codes from 0-19 are read from configuration and sent via SMS.

6.1.16 setparam 1271 X/212 X

operator codes may be configured in 1 SMS. Example: Setparam 1271 16 24602,24603,24605
,here 16
in the configuration.
Downloaded from
www.Manualslib.com
Example: DI1:0 DI2:0 DI3:0 AIN:0.0611 DO1:0 DO2:0
Description
I/O element ID
I/O Element value
Sets digital outputs to ON or OFF state (for some time if needed). Value is written as a row
Example: 'setdigout 01 0 5' will set OUT2 to high level for 5 seconds, while OUT1 to low
To ignore one digital output value and make ON/OFF state only to another digital output
Example: 'setdigout ?1' will set OUT2 to high level for indefinite period of time while OUT1
Sets selected digital output to on or OFF state for a defined period of time.
Example: 'setdigout2 1 5' will set DOUT2 to high level for 5 seconds.
Read parameter value. ID consists of 3 or 4 digits. Detailed list of parameters and IDs can
Example: 'getparam 1115' command will request server IP address.
Sets new value for parameter. ID consists of 3 or 4 digits. Detailed list of parameters and
Example: 'setparam 1115 127.0.0.1' will change configured IP address.
X values can be 1,2,3.
If X is from 0 to 49, X means index of operator code which has to be configured. Up to 20
th
th
th
, 17
and 18
operator codes are set. Note! Other operator codes are left unchanged