Table 14: Reporting Summaries - Bosch D9068 Operation And Installation Manual

Fire communicator
Table of Contents

Advertisement

D9068 | Operation and Installation Guide | Appendix C: Fire Communicator Report
.

Table 14: Reporting Summaries

Report
SIA
Description
Code
Point Fire
FA pppp
Alarm
Point Water-
SA pppp
flow Alarm
Point
Supervisory
SS pppp
Alarm
Point Monitor
UA pppp
Alarm
Point Fire
FT pppp
Trouble
Point Water-
ST pppp
flow Trouble
Point
Supervisory
ST pppp
Trouble
Point Monitor
UT pppp
Trouble
Point Fire
FR pppp
Alarm Restore
Point Water-
SH pppp
flow Restore
Point
Supervisory
SR pppp
Restore
Point Monitor
UR pppp
Restore
Point Fire
Trouble
FJ pppp
Restore
Point Water-
flow Trouble
SJ pppp
Restore
Point
Supervisory
SJ pppp
Trouble
Restore
Point Monitor
Trouble
UJ pppp
Restore
Open Reset
OR iii
Low Battery
YT
Low Battery
YR
Restore
Refer to Note 1 through Note 9 above.
Bosch Security Systems, Inc. | 3/13 | F01U071094-07
Point-Related Events
SIA
Contact
Description
ID Code
1 110 aa
Fire Alarm
ppp
Sprinkler
1 113 aa
Alarm
ppp
Sprinkler
1 200 aa
Supervisory
ppp
Untyped Zone
1 140 aa
Alarm
ppp
1 373 aa
Fire Trouble
ppp
Sprinkler
1 373 aa
Trouble
ppp
Sprinkler
1 373 aa
Trouble
ppp
Untyped Zone
1 373 aa
Trouble
ppp
Fire
3 110 aa
Restoral
ppp
Sprinkler
3 113 aa
Alarm
ppp
Restore
Sprinkler
3 200 aa
Restoral
ppp
Untyped Zone
3 140 aa
Restoral
ppp
Fire Trouble
3 373 aa
Restore
ppp
Sprinkler
3 373 aa
Trouble
ppp
Restore
Sprinkler
3 373 aa
Trouble
ppp
Restore
Untyped
3 373 aa
Trouble
ppp
Restore
Disarm From
1 401 aa
Alarm
iii
System
1 302 aa
Battery
000
Trouble
System
3 302 aa
Battery
000
Restoral
4/2
Contact ID
Code
Description
Default
Values
Fire Alarm
0P
Waterflow
0P
Fire
0P
Supervisory
General
0P
Alarm
Fire
6P
Trouble
Fire
6P
Trouble
Fire
6P
Trouble
Fire
6P
Trouble
Fire Alarm
3P
Waterflow
3P
Fire
3P
Supervisory
General
3P
Alarm
Fire
3P
Trouble
Fire
3P
Trouble
Fire
3P
Trouble
Fire
3P
Trouble
O/C By User
9F
Low System
F9
Battery
Low System
E9
Battery
Summary
2
Modem IIIa
Description
Fire Alarm Point =
ppp
Fire Alarm Point =
ppp
Fire Supervision
Point = ppp
Alarm Point = ppp
Fire Trouble Point =
ppp
Fire Trouble Point =
ppp
Fire Trouble Point =
ppp
Trouble
Point = ppp
Fire Restoral Point
= ppp
Fire Restoral Point
= ppp
Fire Restoral Point
= ppp
Restoral From Alarm
Point = ppp
Fire Trouble
Restoral Point = ppp
Fire Trouble
Restoral Point = ppp
Fire Trouble
Restoral Point = ppp
Restoral Point = ppp
Sensor Reset ID =
iii
Battery Low
Battery Restoral
57

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents