Table 11: Reporting Summaries

Report
SIA
Description
Code
Point Fire Alarm
FA pppp
Point Waterflow
SA pppp
Alarm
Point
Supervisory
SS pppp
Alarm
Point Monitor
UA pppp
Alarm
Point Fire
FT pppp
Trouble
Point Waterflow
ST pppp
Trouble
Point
Supervisory
ST pppp
Trouble
Point Monitor
UT pppp
Trouble
Point Fire Alarm
FR pppp
Restore
Point Waterflow
SH pppp
Restore
Point
Supervisory
SR pppp
Restore
Point Monitor
UR pppp
Restore
Point Fire
FJ pppp
Trouble Restore
Point Waterflow
SJ pppp
Trouble Restore
Point
Supervisory
SJ pppp
Trouble Restore
Point Monitor
UJ pppp
Trouble Restore
Open Reset
OR iii
Low Battery
YT
Low Battery
YR
Restore
AC Fail
AT
AC Fail Restore
AR
Auto Test
RP
1/05 | F01U002505B
Appendix C
Point-Related Events
SIA
Contact ID
Description
Code
Fire Alarm
1 110 aa ppp
Sprinkler
1 113 aa ppp
Alarm
Sprinkler
1 200 aa ppp
Supervisory
Untyped Zone
1 140 aa ppp
Alarm
Fire Trouble
1 373 aa ppp
Sprinkler
1 373 aa ppp
Trouble
Sprinkler
1 373 aa ppp
Trouble
Untyped Zone
1 373 aa ppp
Trouble
Fire Restoral
3 110 aa ppp
Sprinkler
3 113 aa ppp
Alarm Restore
Sprinkler
3 200 aa ppp
Restoral
Untyped Zone
3 140 aa ppp
Restoral
Fire Trouble
3 373 aa ppp
Restore
Sprinkler
Trouble
3 373 aa ppp
Restore
Sprinkler
Trouble
3 373 aa ppp
Restore
Untyped
Trouble
3 373 aa ppp
Restore
Disarm From
1 401 aa iii
Alarm
System
Battery
1 302 aa 000
Trouble
System
Battery
3 302 aa 000
Restoral
AC Trouble
1 301 aa 000
AC Restoral
3 301 aa 000
Automatic
1 602 aa 000
Test
4/2 Code
Contact ID
Default
Description
Values
Fire Alarm
0P
Waterflow
0P
Fire
0P
Supervisory
General Alarm
0P
Fire Trouble
6P
Fire Trouble
6P
Fire Trouble
6P
Fire Trouble
6P
Fire Alarm
3P
Waterflow
3P
Fire
3P
Supervisory
General Alarm
3P
Fire Trouble
3P
Fire Trouble
3P
Fire Trouble
3P
Fire Trouble
3P
O/C By User
9F
Low System
F9
Battery
Low System
E9
Battery
AC Loss
F8
AC Loss
E8
Periodic Test
EE
Report
EN | 49
2
Modem IIIa
Description
Fire Alarm Point = ppp
Fire Alarm Point = ppp
Fire Supervision
Point = ppp
Alarm Point = ppp
Fire Trouble
Point = ppp
Fire Trouble
Point = ppp
Fire Trouble
Point = ppp
Trouble Point = ppp
Fire Restoral
Point = ppp
Fire Restoral
Point = ppp
Fire Restoral
Point = ppp
Restoral From Alarm
Point = ppp
Fire Trouble Restoral
Point = ppp
Fire Trouble Restoral
Point = ppp
Fire Trouble Restoral
Point = ppp
Restoral Point = ppp
Sensor Reset ID = iii