Preset Speeds - Toshiba TOSVERT-130G2+ Operation Manual

High performance transistor inverter igbt digital series
Table of Contents

Advertisement

TOSHIBA
8.3.4

7 Preset Speeds

The multispeed function provides the user with up to seven preset speed
frequencies. An eighth speed is available when including the remote input
reference signal. These frequencies (Sr1~Sr7) must be pre-selected. By
presetting parameters Sr1~Sr7 the user is able to operate at any of these
speed frequencies, either forward or reverse, simply by using the method
illustrated below:
Function Function
No.
Name
1st speed
2nd speed
6
3rd speed
4th speed
5th speed
6th speed
7th speed
Note:
All acc/dec times reflect the acc/dec parameter settings which are in effect. These
acc/dec settings are located in 1st Function #2.
Key
The inverter must be placed in the monitor mode and stopped (0.0Hz)
MON
before activating any of the preset speeds.
2ND
Engages the preset speed feature. Pressing a key 1-7 selects the
respective preset speed frequency (Sr1~Sr7).
1
thru
7
Sets a forward run
Sets a forward run
The inverter's output frequency increases to the selected preset
RUN
frequency. The attached motor will accelerate to that frequency.
The inverter's output frequency decreases to zero (0Hz). The attached
STOP
motor will decelerate to a stop.
Multi-Speed Run Frequencies
Adjustment
Display
Range
LL to UL setting value
LL to UL setting value
LL to UL setting value
LL to UL setting value
LL to UL setting value
LL to UL setting value
LL to UL setting value
Activating the Preset Speed Function
Action
8 - 8
Factory
Error
Unit
Set
Message
Hz
0
Hz
0
Hz
0
Hz
0
Hz
0
Hz
0
Hz
0
Display
[:value]
Ref.
Page
8-23
8-23
8-23
8-23
8-23
8-23
8-23

Hide quick links: