ection 5 - Procedures
39. Press EN ER to complete date entry (the system will store it).
40.
he display will show "Calibrate Load" option.
41. Press the ESC button to exit the "Calibrate Load" option.
42. Remove the jumper wire and re-connect the black wire #14 to the coil removed earlier.
43. Close the hydraulic/electric tray.
Once a calibration phase has been successfully completed, it is not required to do it again (unless of course
a change to the vehicle such as a replacement sensor requires that calibration be repeated). his is useful if
the calibration procedure is interrupted – the remaining phases can be completed at a later time.
If a calibration phase has been successfully completed, a "REDO" message is displayed:
REDO DYNAMIC: NO
REDO LOADED: NO
REDO EMPTY: NO
If the phase does not need to be repeated, just press ENTER to move on.
If the phase does need to be repeated, press UP or DOWN to change "NO" to "YE " then press ENTER.
JIII eries
NOTE
Continuing partially complete load calibration.
ervice and Maintenance
KYJACK, Page 23