ervice and Maintenance
Load ensing ystem - CE
4.3-1
Flash Code F01: Check HWF
1.
his message is given if the GP102 startup tests have not completed.
-
Check HELP message for more information.
4.3-2
Flash Code F02: Not Ground Mode
1.
his message is given if the machine is not in ground mode (P2-2 must be high).
-
Calibration can only be carried out in ground mode.
4.3-3
Flash Code F03: Not topped
1.
his message is given if the machine is not in ground mode (P2-2 must be high).
-
Check DIAGNOS ICS / SWI CHES to see which function switch is closed.
4.3-4
Flash Code F04: Tilted
1.
his message is given if the machine is tilted.
-
Calibration must be carried out with the machine level. If the machine is level, use the
SE UPS / IL SE UPS to set the GP102 level.
4.3-5
Flash Code F05: Bad Height
1.
his message is given if the height sensor output (P4-3) is out of range at the start of calibration.
-
he height sensor output must be between 1.0V and 4.0V. Check DIAGNOS ICS / SENSORS
to see the output. A reading of 0V or 5V is probably due to a wiring problem.
4.3-6
Flash Code F06: Check Elev
1.
his message is given if the elevation switch (P2-10) is open at the start of calibration, when the operator
has confirmed the "PLA FORM DOWN?" question.
-
If the platform is down, check the elevation switch wiring.
4.3-7
Flash Code F08: Check Elev
1.
his message is given if the elevation switch (P2-10) is closed at the end of the DYNAMIC lift, when the
platform should be fully raised.
-
his message would occur if the UP switch was accidentally opened near the start of the
DYNAMIC lift. If the platform is fully raised, check the elevation switch wiring.
4.3-8
Flash Code F09: Bad Height
1.
his message is given if the height sensor output (P4-3) is out of range at the start of the DYNAMIC
lift.
-
he height sensor output must be between 1.0V and 4.0V. Check DIAGNOS ICS / SENSORS
to see the output.
4.3-9
Flash Code F10: Bad Height
1.
his message is given if the height sensor output (P4-3) is out of range at the end of the DYNAMIC
lift.
-
he height sensor output must be between 1.0V and 4.0V. Check DIAGNOS ICS / SENSORS
to see the output. A reading of 0V or 5V is probably due to a wiring problem.
4.3-10 Flash Code F11: Not Up
1.
his message occurs at the start of the DYNAMIC lift if the operator selects a function other than UP .
-
Select the UP function.
KYJACK, Page 16