Skyjack SJIII 3226 Service Manual page 124

Sjiii conventional series
Hide thumbs Also See for SJIII 3226:
Table of Contents

Advertisement

ection 5 - Procedures
Please Lower
his message is prompting for the platform to be lowered. he DOWN switch should be closed.
Lift Empty
his message is displayed while the platform is being raised to the next measurement height, when an EMP Y
platform is being calibrated.
Lift Loaded
his message is displayed while the platform is being raised to the next measurement height, when a LOADED
platform is being calibrated.
Lifting
his message is displayed while the platform is being raised, during HEIGH -only calibration.
Measuring #
his message is displayed when the platform is stopped during calibration, when the GP102 takes a measurement.
here will be a short delay while the machine is allowed to stabilize after movement is stopped.
Must Go Down!
his message occurs if the wrong switch is closed when the GP102 is waiting for the platform to be lowered.
Must Go Up!
his message occurs if the wrong switch is closed when the GP102 is waiting for the platform to be raised.
Please Wait
his message indicates that the GP102 is busy; the delay will be short (no more than 5 s).
Lower Empty
his message is displayed while the platform is being lowered to the next measurement height, when an EMP Y
platform is being calibrated.
Lower Loaded
his message is displayed while the platform is being lowered to the next measurement height, when an EMP Y
platform is being calibrated.
Lowering
his message is displayed while the platform is being lowered, during HEIGH -only calibration.
Total Data:
his message is displayed at the end of each phase, to confirm the number of measurements recorded by the
GP102.
Caldate
his message is prompting for the date to be entered; it is stored to identify when the machine was
calibrated.
he last calibrate date can be viewed in DIAGNOS ICS / LOG. Press LEF & RIGH to select the flashing digits.
Press UP & DOWN to change the flashing digits. Press EN ER when the entry is complete. IMPOR AN : he
date 00/00/00 is not allowed!
Finished
his message confirms that calibration is complete and successful.
JIII eries
ervice and Maintenance
KYJACK, Page 19