Log In to the PCS400R and Access the Main Menu

* Note : The PCS400R must be connected to an IP network for SSH client access. For direct access to the PCS400R Service Port, use the FTDI
TTL-USB cable (P/N TTL-232R-5V-AJ). See also "Network and Communication Setup" above for further information.
1 Establish communication with the PCS400R using an SSH client or via a direct connection to the PCS400R Service Port.
Once communication is established, you should see a login prompt. (If the login prompt is not automatically displayed, press Enter to refresh the
screen.)
2 At the login as: prompt, type admin and press Enter.
3 At the Password: prompt, type the admin password and press Enter.
4 At the Command > prompt, either:
•  Press Enter to display the PCS400R Main Menu (See example below).
•  Type the desired command and press Enter.
The following sections describe each of the configuration commands.
* Note: You can always press Enter at the Command > prompt to display the PCS400R Main Menu.
Example: PCS400R Main Menu
System information
info
setip
TCP/IP Setup Menu
tz
Timezone setup
time
Time setup
pwd
Change password
portal
Select the portal application
monitor
System monitor
shut
Shutdown the system
reset
System Reset
exit
End the session
Command >