Setting Up the Pro:Centric Network

This section describes how to complete the initial network configuration for the PCS400R. See also typical setup and VPN network connections
diagrams above.
1 If your system is using ASI output, make the following connections; otherwise, go to step 2.
•  Connect a 75 ohm BNC-to-BNC coaxial cable between ASI OUT on the PCS400R and ASI IN on the modulator.
•  Connect an RF coaxial cable between IF OUT on the modulator and IF IN on the upconverter.
* Note : The BNC cable must be less than 9.2 meters in length.
2 To enable remote management, connect one end of a CAT5 RJ-45 Ethernet cable to the Control Port on the PCS400R rear panel, and connect the
other end of the cable to the institution's network.
3 Connect the PCS400R power supply to the POWER connector on the PCS400R rear panel. Then, plug the AC power cord into a powered AC line
receptacle. When power is applied, the PWR (Power) LED on the PCS400R front panel will initially flash red and then turn green (blinking during
boot-up).
The boot-up process for the PCS400R may take several minutes. When boot-up is complete, the PWR LED on the PCS400R front panel will light
continuously green.
4 Once the PWR LED is lit continuously (no longer blinking), use the FTDI TTL-232R-5V-AJ cable to connect a PC to the Service Port on the PCS400R
rear panel.
5 Using HyperTerminal or an equivalent terminal emulation programme on the PC, configure the serial port as follows:
- Bits per second/baud = 115,200
- Data bits = 8
- Parity = None
- Stop bits = 1
- Flow Control = None
* Note: To avoid configuration errors, make sure the keyboard settings on the terminal emulator assign the backspace character to Ctrl + H
(ASCII 8).
Once the connection is established, you should see a login prompt. (If the login prompt is not automatically displayed, press Enter to refresh the
screen.)
6 At the login as: prompt, type admin and press Enter. Then, at the password: prompt, type Password4Partners (case-sensitive)
and press Enter.
* Note: After the initial system setup is complete, it is highly recommended that you change the admin user pass-
word from its default value. See "Change the Login Password" on page 30 for further information.
The system will display a prompt for you to select the Pro:Centric portal application you will be using:
You must select a portal application to continue.
Available portal applications are:
1
pca (Java)
2
pcd (HTML)
Enter 1 or 2 to select a portal application: