Saftronics CIMR-VG5U Installation & Quick Start Manual page 98

Vg5 series revision f general purpose flux vector inverter with avc
Table of Contents

Advertisement

Appendix
VG5 Parameters
Name
Parameter
Function
(Digital Operator
No.
Display)
H3-06
(Terminal 16 Gain)
H3-07
(Terminal 16 Bias)
Signal Level
Selection Terminal
H3-08
14
(Term 14 Signal)
Multi-function
Analog Input
H3-09
Terminal 14
(Terminal 14 Sel)
Terminal 14 Gain
H3-10
(Terminal 14 Gain)
Terminal 14 Bias
H3-11
(Terminal 14 Bias)
Analog Input Filter
Time Constant
H3-12
(Filter Avg Time)
98
Setting
Setting
Factory
Range
Unit
Setting
0.0~
0.1%
100.0
1000.0
–100.0
0.1%
0.0
~ +100.0
0: (0 - 10 VDC)
0, 1, 2
1
2
1: (–10 +10 VDC)
2: (4 - 20 mA)
The function choices for terminal
14 are the same as the choices
1~1F
1
1F
for terminal 16 [ see H3-05},
except that [setting 0] "Auxiliary
Reference" is not available.
0.0~
0.1%
100.0
1000.0
–100.0
~
0.1%
0.0
+100.0
0.00~
0.01s
0.00
2.00
Change
Remarks
Operation
(Digital Operator Display)
o: Enabled
x: Disabled
VG5 Installation & Quick-Start Manual
Parameter Access Level
during
V/f
Open
V/f
w/
Loop
PG
Vector
o
B
B
B
o
B
B
B
x
A
A
A
x
A
A
A
o
A
A
A
o
A
A
A
x
A
A
A
User
Flux
Setting
Vector
B
B
A
A
A
A
A