CE CONFORMANCE - Electro-Magnetic Compatibility (EMC) Compliance
In order to conform to EMC standards, exclusive-use methods are required for line filter applica-
tion, cable shielding and inverter installation. An outline of the methods follows.
The line filter and the inverter must be mounted on the same metal plate. The filter should be
mounted as close to the inverter as practical. Keep cable as short as possible. The metal plate should
be securely grounded. The ground of the line filter and inverter must be bonded to the metal plate
with as much area as possible.
For line power input cable, screened cable is recommended at least within the panel. The screen of
the cable should be connected to a solid ground. For the motor cable, screened cable (max. 20m)
must be used and the screen of the motor cable is connected to ground at both ends by a short con-
nection, using as large an area as practical.
The following table and figures show the line filter list for EMC standards and the installation/wir-
ing of inverter and line filter.
Inverter
Model
CIMR-
VG5Uxxxx
40P4
40P7
41P5
42P2
43P7
44P0
45P5
47P5
4011
4015
4018
4022
4030
4037
4045
4055
4075
4110
4160
4185
4220
4300
VG5 Installation & Quick-Start Manual
Line Filter List for EMC Standards
Line Filter (Manufactured by Schaffner)
Rated
Model
Current
(A)
FS4874-7/07
7
FS4874-18/07
18
FS4874-30/07
30
FS4874-42/07
42
FS4874-55/07
55
FS4874-75/34
75
FS4874-100/35
100
FS4874-130/35
130
FS4874-180/07
180
FS4874-300/99
300
FS4874-400/99
400
FS4874-500/99
500
FS4874-600/99
600
FS4874-900/99
900
CE Conformance Information
Mass
Dimensions (mm)
W D H
(kg)
50 126 255
1.1
55 142 305
1.7
60 150 335
1.8
70 185 329
2.8
80 185 329
3.1
80 220 329
4.0
90 220 379
5.5
110 240 429
7.5
110 240 438
11
300 564 160
15
300 564 160
22
300 564 160
19.5
300 564 160
20.5
300 564 160
33.5
Appendix
109