Saftronics CIMR-VG5U Installation & Quick Start Manual page 80

Vg5 series revision f general purpose flux vector inverter with avc
Table of Contents

Advertisement

Appendix
VG5 Parameters
Name
Parameter
Function
(Digital Operator
No.
Display)
PID Feedback Ref-
erence Missing
B5-12
Detection Selection
<1110>
(Fb Los Det Sel)
PID Feedback Ref-
erence Missing
B5-13
Detection Level
<1110>
(Fb los Det Lvl)
PID Feedback Ref-
erence Missing
B5-14
Detection Time
<1110>
(Fb los Det Time)
Dwell Frequency at
Start
B6-01
(Dwell Ref @Start)
Dwell Time at Start
(Dwell Time @
B6-02
Start)
Dwell Frequency at
Stop
B6-03
(Dwell Ref @ Stop)
Dwell Time at Stop
(Dwell Time @
B6-04
Stop)
Droop Control Gain
B7-01
(Droop Quantity)
Droop Control
Delay Time
B7-02
(Droop Delay Time)
80
Setting
Setting
Factory
Range
Unit
Setting
(Digital Operator Display)
0: PID feedback missing
1: PID feedback missing
0~2
1
0
2: PID feedback missing
0~100
1%
0
0.0~
0.1s
1.0
25.5
0.0~
0.1Hz
0.0
400.0
0.0~
0.1s
0.0
10.0
0.0~
0.1Hz
0.0
400.0
0.0~
0.1s
0.0
10.0
0.0~
0.1%
0.0
100.0
0.03~
0.01s
0.05
2.00
Change
during
Remarks
Operation
o: Enabled
x: Disabled
detection disabled. (Dis-
abled)
detection enabled. (Alarm)
Operation continues after
detection, "Fbl" alarm is dis-
played.
detection enabled. (Fault)
Inverter output is shut off
after detection, "Fbl" is dis-
played.
VG5 Installation & Quick-Start Manual
Parameter Access Level
V/f
Open
V/f
w/
Loop
PG
Vector
x
A
A
A
x
A
A
A
x
A
A
A
x
A
A
A
x
A
A
A
x
A
A
A
x
A
A
A
o
-
-
-
o
-
-
-
User
Flux
Setting
Vector
A
A
A
A
A
A
A
A
A