Saftronics CIMR-VG5U Installation & Quick Start Manual page 41

Vg5 series revision f general purpose flux vector inverter with avc
Table of Contents

Advertisement

Typical Operation Example by Digital Operator
Description
Power ON
· Displays frequency reference value.
Operation Condition Setting
· Select LOCAL mode.
Forward Jog Run (6Hz)
· JOG run procedure
(Runs while depressing JOG key.)
Frequency Setting
· Change frequency reference value. Digit to
be changed blinks.
· Write-in set value.
· Select output frequency monitor display.
Forward Run
· Forward run (15Hz) Run & FWD LEDs light.
Frequency Reference Value Change
(15~60Hz)
· Select frequency reference value display
· Change set value.
· Write-in set value.
· Select output frequency monitor display.
Reverse Run
· Select reverse run. REV LED lights.
Stop
· Decelerates to stop. Stop LED lights.
VG5 Installation & Quick-Start Manual
Key Sequence
LOCAL
REMOTE LED (SEQ, REF) OFF
REMOTE
JOG
DATA
ENTER
Change the value
by depressing
RESET
DATA
ENTER
ESC
RUN
DATA
ENTER
Depress twice.
Change the value
by depressing
RESET
DATA
ENTER
DATA
ENTER
FWD
REV
STOP
RESET
Chapter 2 - Operation
Trial Operation
Digital Operator Display
Frequency Ref
U1-01 = 0.00 Hz
Frequency Ref
0 00.00 Hz
Frequency Ref
01 5 .00 Hz
Entry Accepted
Frequency Ref
01 5 .00 Hz
Output Freq
U1-02 = 0.00 Hz
Output Freq
U1-02 = 15.00 Hz
Frequency Ref
0 15.00 Hz
Frequency Ref
06 0 .00 Hz
Entry Accepted
Output Freq
U1-02 = 60.00 Hz
Output Freq
U1-02 = -60.00 Hz
Output Freq
U1-02 = 0.00 Hz
41