Operation By Control Circuit Terminal Signal - Saftronics CIMR-VG5U Installation & Quick Start Manual

Vg5 series revision f general purpose flux vector inverter with avc
Table of Contents

Advertisement

Chapter 2 - Operation
Trial Operation

Operation by Control Circuit Terminal Signal

The diagram below shows a typical operation profile using the control circuit terminal signals.
Typical Operation Example by Control Circuit Terminal Signal
Description
Power ON
· Displays frequency reference value.
REMOTE mode is preset at the factory.
Output Frequency Display
· Switch to output frequency display.
Forward Jog Run (6Hz)
· Close between control circuit terminals 1 &
11, and 7 & 11 closed to perform JOG run.
Run & FWD LEDs illuminate.
· Open between terminals 1 & 11, and 7 & 11
after verifying JOG operation
Frequency Setting
· Input frequency reference via terminal 13
(voltage) or 14 (voltage/current) and verify
the input value with the digital operator.
Output Frequency Display
· Select output frequency monitor display.
Forward Run
· Close between terminals 1 & 11 to perform
forward run.
Stop
· Open between terminals 1 & 11 to stop
operation. Stop LED illuminates.
42
3
1
2
Power ON
Operation
Frequency Setting
Figure 16 Operation Sequence by Control Circuit Terminal Signal
4
Forward
60Hz
Stop
Key Sequence
REMOTE LED (SEQ, REF) ON
VG5 Installation & Quick-Start Manual
Digital Operator Display
Frequency Ref
U1-01 = 0.00 Hz
Output Freq
U1-02 = 0.00 Hz
Output Freq
U1-02 = 6.00 Hz
Frequency Ref
U1-01 = 60.00 Hz
Output Freq
U1-02 = 0.00 Hz
Output Freq
U1-02 = 60.00 Hz
Output Freq
U1-02 = 0.00 Hz