Saftronics CIMR-VG5U Installation & Quick Start Manual page 106

Vg5 series revision f general purpose flux vector inverter with avc
Table of Contents

Advertisement

Appendix
VG5 Parameters
Name
Parameter
Function
(Digital Operator
No.
Display)
User Parameter Ini-
tialization Selection
O2-03
(User Defaults)
kVA Selection
O2-04
(Inverter Model #)
Frequency Refer-
ence Setting
O2-05
Method Selection
(Operator M.O.P.)
Operation Selec-
tion When Digital
Operator is Discon-
O2-06
nected
(Oper Detection)
Elapsed Timer
Setting
O2-07
(Elapsed Time Set)
Elapsed Timer
Selection
O2-08
(Elapsed Time Run)
Initialization Mode
Selection
O2-09
(Init Mode Sel)
106
Setting
Setting
Factory
Range
Unit
Setting
(Digital Operator Display)
0: (No Change)
manufacturer default values
used
1: (Set Defaults)
0, 1, 2
1
0
Sets user specified value as
default.
2: (Clear All)
Clears user defaults
* Not initialized. Sets the
0~FF
1
–*
inverter capacity according
to the model number.
0: (Disabled)
0, 1
1
0
1: (Enabled)
0: (Disabled) Operation contin-
ues even if the digital opera-
tor is disconnected.
0, 1
1
0*
1: (Enabled) Inverter fault
when the digital operator is
disconnected.
* When 02-09=1, the value is 1.
0~
1 hour
65535
0: (Power - On Time)
0, 1
1
0
1: (Running Time)
0: (Japanese spec)
1: (American spec)
2: (European spec)
3: (OMRON spec)
0~3
1
0
When 02-09 = 1 or 2, it is
added by
When 02-09 = 0 or 3, it is
added by
Change
during
Remarks
Operation
o: Enabled
x: Disabled
x
x
x
x
x
x
x
.
<1032>
.
<1040>
VG5 Installation & Quick-Start Manual
Parameter Access Level
V/f
Open
Flux
V/f
w/
Loop
Vector
PG
Vector
B
B
B
B
B
B
B
B
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
User
Setting

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cimr-vg5

Table of Contents