Saftronics CIMR-VG5U Installation & Quick Start Manual page 92

Vg5 series revision f general purpose flux vector inverter with avc
Table of Contents

Advertisement

Appendix
VG5 Parameters
Name
Parameter
Function
(Digital Operator
No.
Display)
Motor 2 Rated
Current
E5-01
(Motor Rated FLA)
Motor 2 Rated Slip
E5-02
(Motor Rated Slip)
Motor 2 No-load
Current
E5-03
(No-Load Current)
Motor 2 Number of
poles
E5-04
(Motor 2 # Poles)
Motor 2 Line-to-line
Resistor
E5-05
(Motor 2 term
Ohms)
Motor 2 Leak Induc-
tance
E5-06
(Motor 2 Leak)
Note 13: This value is for the 200V class. For 400V class, the value is twice that of 200V class. For 575V class, modify the values by 575/200
Note 14: Control mode is determined by E3-01.
PG Constant
F1-01
(PG Pulses/Rev)
Operation Selec-
tion at PG Open
F1-02
Circuit
(PG Fdbk Loss Sel)
Operation Selec-
tion at Overspeed
F1-03
(PG Overspeed
Sel)
Operation Selec-
tion at Deviation
F1-04
(PG Deviation Sel)
PG Rotation
F1-05
(PG Rotation Sel)
PG Division Rate
PG --Pulse monitor
F1-06
(PG Output Ratio)
Integral Value
during Accel/decel
F1-07
Enable/disable
(PG Ramp PI/I Sel)
Overspeed
Detection Level
F1-08
(PG Overspd Level)
* When access level is BASIC (A1-03), constant is not displayed unless the option is connected.
92
Setting
Setting
Factory
Range
Unit
Setting
(Digital Operator Display)
0.00~
0.1A*
1.9**
1500.0
0.00~
0.01Hz 2.90**
20.00
0.00~
* Setting unit is 0.01A for mod-
0.01A*
1.20**
1500.0
els of 7.5 kW or less.
** Factory setting differs
2~48
1 pole
4
depending on inverter capacity
(02-04).
0.000~
0.001
9.842**
65.000
W
0.0~
0.1%
18.2**
30.0
0~
*When 02-09=1 (USA), 2
1
600*
60000
(EUR.), factory setting is 1024
0: (Ramp to Stop)
1: (Coast to Stop)
0~3
1
1
2: (Fast-Stop)
3: (Alarm Only)
0: (Ramp to Stop)
1: (Coast to Stop)
0~3
1
1
2: (Fast-Stop)
3: (Alarm Only)
0: (Ramp to Stop)
1: (Coast to Stop)
0~3
1
3
2: (Fast-Stop)
3: (Alarm Only)
0: Counter-clockwise
0, 1
1
0
1: Clockwise
Effective only when control cir-
1~132
1
1
cuit board PG-B2 is used.
0: (Disabled)
0, 1
1
0
1: (Enabled)
0~120
1%
115
Change
during
Remarks
Operation
o: Enabled
x: Disabled
(Fwd = C.C.W.)
(Fwd = C.W.)
VG5 Installation & Quick-Start Manual
Parameter Access Level
V/f
Open
V/f
w/
Loop
PG
Vector
A
A
A
x
(Note
(Note
(Note
14)
14)
14)
A
A
A
x
(Note
(Note
(Note
14)
14)
14)
A
A
A
x
(Note
(Note
(Note
14)
14)
14)
-
A
-
x
(Note
(Note
(Note
14)
14)
14)
A
A
A
x
(Note
(Note
(Note
14)
14)
14)
A
-
A
x
(Note
(Note
(Note
14)
41)
14)
x
-
Q
-
x
-
B
-
x
-
B
-
x
-
B
-
x
-
B
-
x
-
B
-
x
-
B
-
x
-
A
-
User
Flux
Setting
Vector
A
(Note
14)
A
(Note
14)
A
(Note
14)
A
(Note
14)
A
(Note
14)
A
(Note
14)
Q
B
B
B
B
B
-
A