Install a Rack Mount (Optional)

RACK-1 Rack-Mounting Kit

Follow these instructions to attach the PortMaster Communications Server to a rack
with the RACK-1 rack-mounting kit.
Required Equipment
Four 12-24x1/2-inch pan head screws
Four 4x3/4-inch sheet metal screws
Flathead screwdriver
Number 1 Phillips screwdriver
Rack with universal Electronic Industries Association (E.I.A.) spacing
Procedure
1.
Unscrew (counterclockwise) the black plastic screws that secure the feet to the
bottom of the PortMaster.
Retain the feet and the center expansion sleeve in each foot in place on the bottom
of the PortMaster.
2.
Turn the rack mount unit upside down and align its four holes with the centers
of the holes in the PortMaster feet.
The front of the PortMaster case sits about 1/8 inch in front of the mounting shelf
flanges.
3.
Press—do not screw—a 4x3/4 inch sheet metal screw into four mounting shelf
holes.
4.
Turn the unit right side up by lifting from the front and rear of the PortMaster.
5.
Install the unit in the rack with the four 12-24x1/2-inch pan head screws.
2-6