Observing Boot Messages

If you are having difficulty booting the PortMaster and are unable to isolate the
problem by observing LED behavior, boot the PortMaster in console mode and check
the boot messages.
Follow these instructions to check boot messages:
1.
Attach a console (see "Connect a Console" on page 2-7).
2.
Turn on power (see "Turn On Power" on page 2-14).
3.
Observe the boot messages displayed on the console screen.
Note – Boot messages vary slightly, depending on the version of the PROM and
ComOS.
PortMaster Diagnostic Boot Messages:
Testing Low Memory....
Testing System Clock....
Testing System Memory.... 1024K
Checking Boot Rom....
Calibrating.... 33MHz
Starting FLASH Boot.....
Booting From Flash Type AM29F040
Loading Image at 0fff0000
17082 flash copy complete
Verifying Load Module Checksum...
Starting Load Module...
Loading kernel...586988 bytes
Testing High Memory... . 1024K
ISDN found in slot 1 - Testing memory.. 512K
Found 11 ports....
ether0 active... 64K burst-IO
Running ComOS...
PortMaster Console login:
Troubleshooting
Observing Boot Messages
A-5