Omron NL-200 User Manual page 30

Led lighting controller
Table of Contents

Advertisement

Set continuous mode
The output is set to continuous mode at a percentage of full brightness.
RSc,s
Where:
c = output channel (1 or 2)
s = setting in percent (s = 0 to 100)
Set switched mode
The output is set to switched mode at a percentage of full brightness.
RWc,s
Where:
c = output channel (1 or 2)
s = setting in percent (s = 0 to 100)
Set selected mode
The output is set to selected mode with two brightness settings.
RUc,s,t
Where:
c = output channel (1 or 2)
s = brightness 1 setting in percent (s = 0 to 100)
t = brightness 2 setting in percent (t = 0 to s)
Set pulse mode
The output can be set up to pulse on a trigger input. The delay from trigger to the start of the pulse,
the length of the pulse and the brightness are configurable.
An error is generated if the brightness setting requires a current greater than 20A or if the combination
of pulse width and setting is not allowed.
RTc,p,d,s
RTc,p,d,s,r
Where:
c = output channel (1 or 2)
Set the Option Flags
REc,m
Where:
c = output channel (1 or 2)
m = flags:
bit 1 =
bit 2 =
NL-200 Series Controller User Manual
p = pulse width in milliseconds (0.02 to 999)
d = delay from trigger to pulse in milliseconds (0.02 to 999)
s = setting in percent (s = 0 to 999)
r = retrigger delay. This parameter is optional
0
E flag set (error detection enabled)
1
E flag cleared (error detection disabled)
0
P flag set (positive triggers)
1
P flag cleared (negative triggers)
Command Configuration
(NL-220, NL-220F)
11-3