8 Front Panel
Configuration
(NL-200, NL-220, NL-220F)
8.1 Startup
For controllers with a front panel, On power up, the NL-
2XX will display "b r" for 5 seconds, then '8.8.8.' to test the
display is working, then 'NL2', then '00', followed by the
firmware version number, eg '001', and then will be ready
for operation. To show that the unit is operating normally, an
alternating pattern is drawn on the display. Once a light is
connected, the controller will sense it, as described below in
Lighting Setup.
Note, if light(s) are connected and have no rating specified
for them, then an error is indicated. To set the rating refer to
section 7.1.
The overall structure of configuration is given to the right.
To configure the controller from the keypad, press and hold
SEL for 1 second. 'CH1' will be displayed. Use UP and
DOWN to select which feature to set up.
Pressing and holding MODE at any time will cancel the
operation.
Using the keypad it is possible to set the configuration for
each channel, set a keylock code so that unauthorised
users cannot change any settings, set the internal trigger
timer, view trigger status and set the voltage or current rat-
ing of each of the channels.
8.2 Setting the Lighting Rating
This is described in Lighting Setup (Section 7).
8-1
NL-200 Series Controller User Manual