4.7.2 Distributor DIP switch settings
The following DIP switch settings are required when installing the distributor using bus wiring.
– Distributor ID settings #1 – #8: applicable DIP switches (A) must be configured at each distributor.
– Room number ID settings A – f: applicable DIP switches (B) must be configured according to each button
number of the lobby stations and rooms.
: For the purpose of an explanation, numbers are written on the name plates of each call button of the lobby stations.
A
Example: When configuring room number 20, set the DIP switch of the applicable distributors T.
DIP SW
ON
1 2 3 4 5 6 7 8
A
A
A
P
O
A
L
K
A
H
G
D
C
Distributor ID settings A
Setting
DIP switch
Distributor
ON
OFF
ID #1
1 2 3 4 5 6 7 8
Distributor
ON
OFF
ID #2
1 2 3 4 5 6 7 8
Distributor
ON
OFF
ID #3
1 2 3 4 5 6 7 8
Distributor
ON
OFF
ID #4
1 2 3 4 5 6 7 8
B
B
#4
N
M
B
#3
J
I
B
#2
F
E
B
#1
B
A
Setting
Distributor
ID #5
Distributor
ID #6
Distributor
ID #7
Distributor
ID #8
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
X
W
T
S
DIP switch
ON
OFF
1 2 3 4 5 6 7 8
ON
OFF
1 2 3 4 5 6 7 8
ON
OFF
1 2 3 4 5 6 7 8
ON
OFF
1 2 3 4 5 6 7 8
4. Installation
17
18
1
19
20
21
22
23
24
25
26
27
28
29
30
31
32
A
B
#8
A
B
A
#7
Z
B
A
#6
V
B
#5
R
Termination
DIP switch
Farthest end
ON
OFF
distributor
1 2 3 4 5 6 7 8
Not farthest
ON
OFF
end distributor
1 2 3 4 5 6 7 8
Y
U
Q