5.1 System conditions and limitations

Please note the following system conditions and limitations.
R Only one call or monitoring session can be handled at a time.
– If the call button for the same lobby station is pressed multiple times, the last call button pressed has priority.
– If the call buttons for multiple lobby stations are pressed, the first call button pressed has priority.
– The main monitor cannot monitor with the lobby station when the lobby station is in use (monitoring with other
devices, on call).
R When lobby stations are connected to extension boxes, main monitors cannot monitor the outside with any of the
lobby stations.
R Even when multiple lobby stations are connected to an extension box,
(except for VL-MV10 (bus-powered main monitor)).
R All calls and monitoring sessions are disconnected after the "timeout" time elapses. The time is 90 seconds for
calls and 180 seconds for monitoring.

5.2 Lobby station operations

5.2.1 Calling a resident
Enter the resident's call button to call.
R
indicator flashes in red while calling the resident.
R After the resident answers the call,
R When the door is unlocked, the audio guidance is announced from the lobby station, and the
in blue.
indicator lights in amber.

5. Basic Operations

is displayed for all of the lobby stations
indicator lights