Panasonic VL-VM701 Installation And Operating Instructions Manual page 33

Vl-vm series. video intercom system - loby station/distributor
Table of Contents

Advertisement

7
When using bus wiring:
Insert the wires from the distributor or the extension
box into the 6-pin terminal block, tighten the terminal
block screws, and then attach the terminal block to
the line connection terminals.
R Connect the wires as follows.
L1 and L2: Distributor or extension box
Camera module
A
A
6-pin terminal block
B
Wires from distributor or extension box (bus
wiring)
8
Make sure to reattach the terminal cover to the
terminal of the camera module.
9
When using bus wiring and a VL-V703 extension
box:
Make the following connections for the extension
box. Refer to the following items of the
documentation of the VL-V900/VL-V901 series
(including the VL-V703 extension box) for details
about installation.
– Included items
– Device diagrams
– How to connecting wiring (stripping wires and
cables, wire release button, or cable release
button)
Download the documentation from the Web site
below.
https://panasonic.net/cns/pcc/support/intercom/
v900
a. Connect the wires from the power supply unit.
R Connect the wires as follows.
DC IN: Power supply unit
b. Insert the wires from the lobby station.
R Connect the wires as follows.
L1 and L2: Lobby station
c. Insert the wires from the distributor
R Connect the wires as follows.
V700/VM701 L1 and L2: Distributor
7 mm
B
10
When using bus wiring and VL-VM701
distributor:
Make the following connections for the distributor.
a. Remove the cable cover screws and then remove
the cable covers.
Distributor
A
A Screws
B Cable covers
b. Insert the wires from the power supply unit into
the DC terminal block, tighten the terminal block
screws, and then attach the terminal block to the
DC connection terminals.
R Connect the wires as follows.
DC IN: Power supply unit
c. Insert the wires from the lobby station, extension
box, or previous distributor into the 2-pin terminal
block, tighten the terminal block screws, and then
attach the terminal block to the connection
terminals.
R Connect the wires as follows.
IN VM101/VM701 L1 and L2: Lobby station,
extension box, or previous distributor
d. Insert the wires from the next distributor into the
2-pin terminal block, tighten the terminal block
screws, and then attach the terminal block to the
connection terminals.
R Connect the wires as follows.
OUT VM701 L1 and L2: Distributor
e. Insert the wires from the main monitor into the
2-pin terminal block, tighten the terminal block
screws, and then attach the terminal block to the
line connection terminals.
R Connect the wires as follows.
D1 and D2: Main monitor
f. After wiring each terminal to the distributor, use
the cable binders to secure the wires to the cable
binder holes on the top and bottom on the
distributor.
g. Make sure to reattach the cable covers and then
securely fasten the cable cover screws.
4. Installation
A
B
33

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents