Status after change of configuration
The connections are available immediately.
Behavior after power on
The connections are available immediately after system initialization.
6.2.1

Analog signals

The following table contains all signals that are available in the NV connecting list for connec-
tion to the external inputs (NV_...) of the analog output module 4-channel.
Category
Inactive
Central processing unit
Analog variables
Program
generator 1 to
Program
generator 9
Analog PLC out-
put block 10 to
block 18
Multichannel controller module
Controller
Analog inputs
Mathematics
Signal
Analog variable 1 to 64
Channel 1 SP1 to Channel 3 SP1 Setpoint value 1 of program channel 1 to 3
Channel 1 SP2 to Channel 3 SP2 Setpoint value 2 of program channel 1 to 3
Channel 1 SP2 to Channel 3 SP2 Setpoint value 3 of program channel 1 to 3
Channel 1 SP4 to Channel 3 SP4 Setpoint value 4 of program channel 1 to 3
PLC Analog output 13 to 16
PLC Analog output 1 to 16
C01ActualValue to
C04ActualValue
C01Setpoint to C04Setpoint
C01OutpLevelMon to
C04OutpLevelMon
AI01 to AI04
Math01 to Math04
6 Configuration
Description
No signal selected
Analog variable 1 to 64 (via interface)
Signal of PLC analog output 13 to 16
Signal of PLC analog output 1 to 16
Actual value of controller channel 1 to 4
Setpoint value of controller channel 1 to 4
Output level (display value) of controller
module 1 to 4
Measured value of analog input 1 to 4
Result of math function 1 to 4
37