Application Areas Of The Individual Sivacon 8Ps Systems - Siemens SIVACON 8PS Configuration Manual

Busbar trunking system. configuring with lx system. low-voltage power distribution and electrical installation technology
Hide thumbs Also See for SIVACON 8PS:
Table of Contents

Advertisement

3.3

Application areas of the individual SIVACON 8PS systems

Application areas of the individual SIVACON 8PS systems
The individual systems of SIVACON 8PS are designed for the building and industry
application areas. They enable flexible power distribution in building construction and a safe
power supply to electronic loads.
The following table contains information on the application areas:
Location of
Application areas
Use
Public
Banks
buildings
Insurance companies
Internet providers
Computer centres
Broadcasting stations
Shopping centres
Furniture stores
Trade fairs
Airports
Hospitals
Clinics
Office buildings
Industrial
Industrial buildings
buildings
Production environments
Industrial production with
extreme conditions
SIVACON 8PS - Configuring with LX system
Configuration Manual, 10/2011, A5E02194899-02
3.3 Application areas of the individual SIVACON 8PS systems
For power distribution in multi-storey buildings with a
mainly vertical busbar run layout.
To avoid neutral conductor overloading due to electronic
loads subject to harmonics
To prevent interference potentials in the rail enclosure
from negatively influencing operability of loads
If there is a high density of load tap-off points in the
smallest of spaces
If structural conditions permit only a vertical busbar run
layout for power distribution
To protect loads against negative influences of magnetic
field emissions
For power distribution with a mainly horizontal busbar
run layout and IP34 degree of protection
When plug-in tap-off points for loads up to 1250 A are
required
When load tap-off points have to have a high short-
circuit resistance, e.g.
I
= 100 kA / I
= 120 kA
CC
cf
When plug-in tap-off points for loads up to 630 A are
sufficient
When the IP34 degree of protection is sufficient.
When the IP54 degree of protection is sufficient
When the degree of protection IP6x is required.
For power conveyance under extreme production
conditions
For power conveyance outside closed buildings
When a horizontal busbar run layout and the IP68
degree of protection are required
Product description
System
LX
LD
LR
X
-
-
X
-
-
X
-
-
X
-
-
X
-
-
-
X
-
-
X
-
-
X
-
-
X
-
X
-
-
-
X
-
X
-
-
-
-
X
-
-
X
-
-
X
-
-
X
19