Automeasure] Adjustment - Konica Minolta AccurioPress C2070 Daily Maintenance Manual

For operator
Hide thumbs Also See for AccurioPress C2070:
Table of Contents

Advertisement

2.5
How to Operate the Both Sides Adj. Item
17
Press [Close].
18
Press [OK] to finish the adjustment.
2.5.6

[AutoMeasure] Adjustment

Both sides of an adjustment chart output from [Print Mode] are scanned using Intelligent Quality Optimizer
IQ-501, and the both side adjustment is performed automatically. After adjustment, each adjustment value
([Zoom] / [Image Shift] / [Rotate/Skew]) of this screen is updated.
Tips
-
[AutoMeasure] is not available on a machine that is not equipped with Intelligent Quality Optimizer
IQ-501.
-
On the [MACHINE] screen, press [Adjustment] - [Quality Adj.] - [Periodical Both Sides Adj.] in sequence,
and set [Period. Both Sides Auto Adj.] to [ON]. You can then set [Periodical Adjustment] to [ON] or [OFF].
For the tray set to [ON], [Periodical Adjustment] is available.